![Kontron X-Board UPA 63036 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/kontron/x-board-upa-63036/x-board-upa-63036_technical-manual_1996331009.webp)
Kontron Embedded Modules GmbH
Flatpanel Solutions
Marschnerstieg 7
22081 Hamburg / Germany
Fon: +49 (0)40 20 00 90-0
Fax: +49 (0)40 20 00 90-10
http://www.kontron-emea.com/flatpanel
X-BOARD-UPA
08.09.2004
9
4.5
FLEX32 - Interface connector X7
All flat screen signals are LVTTL compatible (3.3V)
Flatfoil 32 Contacts, Right Angle, Bottom Contact
Case/Size: 0,5mm Pitch, Series: 6210 / ZIF
Description Name
Pin
Pin
Name
Description
Power Ground
GND
1
O O
2
SCLK
Data
Clock
Latch pulse
Hsync
3
O O
4
Vsync
First Line Marker
Power Ground
GND
5
O O
6
R0
Panel
Data
R0
Panel Data R1
R1
7
O O
8
R2
Panel
Data
R2
Panel Data R3
R3
9
O O
10
R4
Panel
Data
R4
Panel Data R5
R5
11
O O
12
GND
Power
Ground
Panel Data G0
G0
13
O O
14
G1
Panel Data G1
Panel Data G2
G2
15
O O
16
G3
Panel Data G3
Panel Data G4
G4
17
O O
18
G5
Panel Data G5
Power Ground
GND
19
O O
20
B0
Panel Data B0
Panel Data B1
B1
21
O O
21
B2
Panel Data B2
Panel Data B3
B3
23
O O
24
B4
Panel Data B4
Panel Data B5
B5
25
O O
26
GND
Power
Ground
Data Enable
DE
27
O O
28
SW_VDD
Panel
Power
Panel Power
SW_VDD
29
O O
30
R/L
Right/Left
rotate
Up/Down rotate
U/D
31
O O
32
Q/V
QVGA/VGA
Mode
4.6
Extern Power connector (option) X8
4 Contact Connector, Single Row, Right Angle, Polarization, through hole
Matching Connector: AMP 171822-4
Description Name
Pin
Function
+5,0V DC Power
VCC
1 O
Power Ground
GND
2 O
Power Ground
GND
3 O
+12,0V DC Power
+12V
4 O
4.7
Backlight connector X9
Apply operating voltage for backlight inverter using
connector X9
Board to Cable Connector, single row, 7 Contacts, Right Angle
Case/Size: 1,25mm Pitch, Matching connector: Molex 51021-0700
Description Name
Pin
Function
Not connected
NC
1 O
Not connected
Backlight Dimming
BRIGHT
2 O
Analog signal 0V to 4,8V
Power Ground
GND
3 O
Power Ground
Backlight Power
SW_BACK
4 O
5 / 12 V DC (switched) see 3.4
Backlight Power
SW_BACK
5 O
5 / 12 V DC (switched) see 3.4
Power Ground
GND
6 O
Power Grund
Backlight enable
ENABKL
7 O
Backlight control signal (TTL)