![Kontron X-Board UPA 63036 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/kontron/x-board-upa-63036/x-board-upa-63036_technical-manual_1996331005.webp)
Kontron Embedded Modules GmbH
Flatpanel Solutions
Marschnerstieg 7
22081 Hamburg / Germany
Fon: +49 (0)40 20 00 90-0
Fax: +49 (0)40 20 00 90-10
http://www.kontron-emea.com/flatpanel
X-BOARD-UPA
08.09.2004
5
3.3
Configuration panel power supply JP1
Only for X3, X6, X7
Configuration: Function:
1-2 shorted
+3,3V DC Panel VCC
3-4 shorted
+ 5V DC Panel VCC
5-6 shorted
+ 12V DC Panel VCC
7-8 shorted
Disable Panel Power Sequencing (only for debugging)
Caution !
Only one configuration (Panel VCC) for flatpanel is allowed,
otherwise the board is permanently damaged.
3.4
Configuration backlight power supply JP1
Only for X3, X9
Configuration: Function:
9-10
+ 5V DC
Backlight VCC
11-12
+12V DC
Backlight VCC
13-14
Disable Backlight Power Sequencing (only for debugging)
Caution !
Only one configuration (Backlight VCC) for Backlight is
allowed, otherwise the board is permanently damaged.