Power Consumption
In order to ensure safe operation of the board, the input power supply must monitor the supply voltage and shut
down if the supply is out of range – refer to the actual power supply specification. Please note, in order to keep the
power consumption to a minimal level, boards do not implement a guaranteed minimum load. In some cases, this can
lead to compatibility problems with ATX power supplies that require a minimum load to stay in regulation. The
mITX-BDW-U
board must be powered through either the ATX+12V-4p (4-pole) connector using standard ATX power
supply or by an external 19V power adapter through the I/O power jack.
ATX12V supply: ATX+12V-4p connector must be used in according to the ATX12V PSU standard.
Hot Plugging power supply is not supported. Hot plugging might damage the board.
The requirements to the supply voltages are as follows:
Supply
Min.
Max.
Note
+12 V
11.4 V
12.6 V
Should be
±
5 % for compliance with the ATX specification
+19 V
18.05 V
19.95 V
Should be
±
5 % for mITX-BDW-U compatibility
Total System power example
More detailed Static Power Consumption
On the following pages the power consumption of the T4006 Board is measured under:
1.
Windows 7 Idle
2.
Windows 7 3Dmark 2006
3.
Windows 7 Intel® TAT, 100 % on all CPU cores and GFX
4.
Windows 7 S3 (Sleep)
5.
Windows 7 S5 (Shutdown)
The principal test system and test equipment used:
1.
Tektronix DPO7254
2.
Tektronix TCP202
3.
HP 34401A
4.
ATX rail switch
Power consumption of PSU (power loss), Monitor and HDD are not included.
ATX supplies
BDW-U
PSU
Gnd
Current
Probe
Oscilloscope
Содержание mITX-BDW-U
Страница 1: ... USER GUIDE mITX BDW U User Guide Rev 1 6 Doc ID 1060 4825 KTD N0XXX A ...
Страница 17: ...mITX BDW U User Guide Rev 1 6 www kontron com 17 3 2 mITX BDW U Block Diagram ...
Страница 46: ...mITX BDW U User Guide Rev 1 6 www kontron com 46 System Information ...
Страница 52: ...mITX BDW U User Guide Rev 1 6 www kontron com 52 Silicon Information ACPI Configuration ...
Страница 56: ...mITX BDW U User Guide Rev 1 6 www kontron com 56 Process Configuration Processor Power Management ...
Страница 79: ...mITX BDW U User Guide Rev 1 6 www kontron com 79 South Bridge Configuration SB Serial IO Config ...
Страница 99: ...mITX BDW U User Guide Rev 1 6 www kontron com 99 10 4 Boot ...
Страница 102: ...mITX BDW U User Guide Rev 1 6 www kontron com 102 ...