Installation

OM6040D

Page 3 - 6

ID: 1038-6516, Rev. 1.0

3.4

Mounting

The OM6040D is supplied with fixed mounting brackets for installation in a system cabinet. For
cabinets which are wider than the OM6040D, additional mounting hardware is required which
is not supplied with the OM6040D.

For operation of the OM6040D on a flat surface, desktop or rack shelf, there are no special
mounting fixtures except for the four feet. In this case, for operation the front feet should be
extended to ensure adequate airflow to the OM6040D. Care must also be taken to ensure that
OM6040D cannot fall off of the flat surface.

3.5

Adding or Replacing OM6040D Components

Solution requirements determine the operational configuration of the OM6040D. Therefore, it
may or will be necessary to add, remove, or reconfigure components. AMC modules are nor-
mally supplied with documentation which provides instructions or guidelines on their installation
or replacement. Please refer to this documentation for further assistance.

OM6040D specific components and the backplane, are not user replaceable. The Power Sup-
ply Units (PSUs) and the fan tray are, however, user replaceable.

Replacement of the PSU requires that the main power be removed from the system. Therefore,
it is necessary to ensure that the system is properly prepared for powering down. Once the sys-
tem is powered down, remove the power cable to the PSU, unscrew the retaining screws and
slide it out of the slot. Then install the new PSU, fasten the retaining screws, and reconnect the
main power cable. As required, apply power again to the system.

To replace the fan tray, first remove main power from the system. Then unscrew the two Fan
Bay front panel thumbscrews and remove the fan tray. Install the new fan tray, tighten the two
Fan Bay front panel thumbscrews, and reapply main power as required.

3.6

Cooling Air Filter Maintenance

The OM6040D is provided with a cooling air filter which is located underneath the fans at the
bottom of the subrack. To gain access to the air filter, unscrew the two Fan Bay front panel
thumbscrews and remove the fan tray. The air filter has a frame holder which is used to extract
the filter from the chassis. To inspect, clean, or replace the filter, pull it out of the chassis.

Typically the air filter should be inspected every three months. As required, it should be cleaned
or replaced. If the system is operated in a dusty, oily, or otherwise contaminated environment
the filter should be inspected at shorter intervals, eventually once a month.

3.7

AMC Connector Mating Cycles

The OM6040D backplane connectors and the AMC module card-edge connectors are de-
signed to support at least 200 insertion/extraction cycles. As systems used in a laboratory or
development environment may exceed this number of mating cycles over the product life time,
the card-edge connector of each AMC module should be inspected for wear or damage before
insertion or after extraction. If a card-edge connector exhibits excessive wear or damage, the
AMC module must be replaced to preclude improper operation of the system.

Содержание MicroTCA OM6040D

Страница 1: ...If it s embedded it s Kontron User Guide OM6040D MicroTCA Four Slot Double Full size Single Tier Cube Shelf Doc ID 1038 6516 Rev 1 0 July 13 2010...

Страница 2: ...purposes Information has been carefully checked and is believed to be accurate however no responsibility is assumed for inaccuracies Kontron and the Kontron logo and all other trademarks or registere...

Страница 3: ...Your Safety xi Temperature and High Voltage Safety Instructions xi Special Handling and Unpacking Instructions xi General Instructions on Usage xii Two Year Warranty xiii 1 Introduction 1 3 1 1 Overvi...

Страница 4: ...ID 1038 6516 Rev 1 0 3 3 Prerequisites 3 5 3 3 1 Cooling 3 5 3 3 2 Filler Panels 3 5 3 4 Mounting 3 6 3 5 Adding or Replacing OM6040D Components 3 6 3 6 Cooling Air Filter Maintenance 3 6 3 7 AMC Conn...

Страница 5: ...OM6040D Preface ID 1038 6516 Rev 1 0 Page v List of Tables 1 1 OM6040D Shelf Specifications 1 5 1 2 Standards 1 7 1 3 Related Publications 1 8 3 1 OM6040D Base Solution Configuration 3 3...

Страница 6: ...Preface OM6040D Page vi ID 1038 6516 Rev 1 0 This page has been intentionally left blank...

Страница 7: ...M6040D Shelf Front View 2 4 2 2 OM6040D Shelf Back View 2 5 2 3 OM6040D Shelf Bottom View 2 6 2 4 OM6040D Shelf Top View 2 7 2 5 OM6040D Shelf Left Side View Cutaway 2 8 2 6 Backplane Front View 2 9 2...

Страница 8: ...Preface OM6040D Page viii ID 1038 6516 Rev 1 0 This page has been intentionally left blank...

Страница 9: ...uit product or example shown in this document Kontron reserves the right to change modify or improve this document or the product described herein as seen fit by Kontron without further notice Tradema...

Страница 10: ...evice This symbol and title inform that electronic boards and their compo nents are sensitive to static electricity Therefore care must be taken during all handling operations and inspections of this...

Страница 11: ...important for the user to be electrically discharged before touching the product with his her hands or tools This is most easily done by touching a metal part of your system housing Warning All operat...

Страница 12: ...also to the operational temperature range of the specific board version which must not be exceeded If batteries are present their temperature restrictions must be taken into account In performing all...

Страница 13: ...riginal cost of purchase if appropriate In the event of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to Kontron and the remaining part of the orig...

Страница 14: ...Preface OM6040D Page xiv ID 1038 6516 Rev 1 0 This page has been intentionally left blank...

Страница 15: ...OM6040D Introduction ID 1038 6516 Rev 1 0 Page 1 1 Introduction Chapter 1 1...

Страница 16: ...Introduction OM6040D Page 1 2 ID 1038 6516 Rev 1 0 This page has been intentionally left blank...

Страница 17: ...E Fabric interface Integrated cooling fans The OM6040D supports up to four Double Full size AMC Modules with various possible con figurations of AMC CPUs and peripheral devices Up to two pluggable Pow...

Страница 18: ...Introduction OM6040D Page 1 4 ID 1038 6516 Rev 1 0 Figure 1 1 OM6040D Shelf Perspective View with Feet and Mounting Brackets Power MCH Slot AMC Fan Bay Slots Supply Units PSUs...

Страница 19: ...shelf with PSUs and fans Backplane MicroTCA compliant single tier backplane with Four AMC module connectors One four tongue MCH connector Two pluggable Power Supply Unit connectors Fan connector Inpu...

Страница 20: ...ages 12 V and 3 3 V DC Output power maximum continuous 2 x 300 watts forced air cooling required Current ratings 12 V 0 to 25 A 3 3 V 0 to 2 4 A LED green lights up when both output voltages are prese...

Страница 21: ...s 1 equipment and must be connected to an earthed outlet the socket outlet shall be installed near the equip ment and shall be easily accessible For safe operation the equipment must be protected by a...

Страница 22: ...G AMC 0 Advanced Mezzanine Card Specification R2 0 PICMG AMC 1 PCI Express and Advanced Switching R1 0 PICMG AMC 2 Gigabit Ethernet R1 0 PICMG AMC 3 Storage Interfaces R1 0 IPMI IPMI Intelligent Platf...

Страница 23: ...OM6040D Component Description ID 1038 6516 Rev 1 0 Page 2 1 Component Description Chapter 1 2...

Страница 24: ...Component Description OM6040D Page 2 2 ID 1038 6516 Rev 1 0 This page has been intentionally left blank...

Страница 25: ...over the system slots The OM6040D is delivered with four feet of which the front two are retractable for placement on a desktop or shelf Mounting brackets are also provided for rack mounting The shelf...

Страница 26: ...Component Description OM6040D Page 2 4 ID 1038 6516 Rev 1 0 Figure 2 1 OM6040D Shelf Front View 258 12 240 62 PSU1 Fan Bay AMC Slot 4 AMC Slot 3 MCH PSU2 AMC Slot 2 AMC Slot 1...

Страница 27: ...OM6040D Component Description ID 1038 6516 Rev 1 0 Page 2 5 Figure 2 2 OM6040D Shelf Back View...

Страница 28: ...Component Description OM6040D Page 2 6 ID 1038 6516 Rev 1 0 Figure 2 3 OM6040D Shelf Bottom View front retractable feet...

Страница 29: ...OM6040D Component Description ID 1038 6516 Rev 1 0 Page 2 7 Figure 2 4 OM6040D Shelf Top View 217 72 230 70 215 00 front back...

Страница 30: ...Component Description OM6040D Page 2 8 ID 1038 6516 Rev 1 0 Figure 2 5 OM6040D Shelf Left Side View Cutaway AMC Module Bay f r o n t Fan Fan Air Filter Backplane...

Страница 31: ...interfacing Input power distribution and control for payload management and MCH MCMC power Clock distribution IPMI monitor and control interfacing IPMB L Backplane FRU data storage EEPROM MCMC I C mo...

Страница 32: ...SATA and PCIe channels otherwise improper operation will result If PCIe functionality is implemented the root complex slots must be activated last This can be changed by setting appropriate activation...

Страница 33: ...fix the PSU to the sub rack Input power is supplied via the front panel connector Interfacing to the backplane is achieved via a very high power load Molex connector which interfaces power as well as...

Страница 34: ...e 2 12 ID 1038 6516 Rev 1 0 2 5 Fans The OM6040D s thermal concept currently foresees the use of a four small fans A single fan drawing and a drawing showing the fan tray with all fans is shown in fig...

Страница 35: ...OM6040D Component Description ID 1038 6516 Rev 1 0 Page 2 13 Figure 2 10 Fan Tray with all Fans as Seen from Bottom front rear...

Страница 36: ...Component Description OM6040D Page 2 14 ID 1038 6516 Rev 1 0 This page has been intentionally left blank...

Страница 37: ...OM6040D Installation ID 1038 6516 Rev 1 0 Page 3 1 Installation Chapter 1 3...

Страница 38: ...Installation OM6040D Page 3 2 ID 1038 6516 Rev 1 0 This page has been intentionally left blank...

Страница 39: ...the following Installa tion sections Table 3 1 OM6040D Base Solution Configuration COMPONENT QTY COMPONENT LOCATION DESCRIPTION Subrack 1 Mechanical chassis of OM6040D Backplane 1 Power Supply Unit PS...

Страница 40: ...life or health and may cause damage to the OM6040D or other system components including pro cess side signal conditioning equipment ESD Equipment The OM6040D contains electrostatic sensitive devices E...

Страница 41: ...n the final application 3 3 2 Filler Panels Operation of the OM6040D requires that all slots be fully occupied or appropriate filler panels must be installed to close any open front area s To accompli...

Страница 42: ...f the slot Then install the new PSU fasten the retaining screws and reconnect the main power cable As required apply power again to the system To replace the fan tray first remove main power from the...

Отзывы: