ADA-RK RECESS KIT INSTALLATION INSTRUCTIONS
(For use with all GX, GXT, & EXT hand dryers)
step-01_hardware
10/19/2012 Jay Harnish
STEP 1.
Fig. 1
Verify all hardware is present.
(1) Stainless steel recess box
(4) #8 x 1-1/2” stainless steel wood screw
(4) #10 flat washer
(4) #10-32 nut w/ nylon insert
step-03_recess kit_install
10/19/2012 Jay Harnish
STEP 3.
Fig. 3
Insert the recess box into the rough
wall opening. Run electrical through
conduit entrance as shown. Using the
provided wood screws, secure recess
box to wall studs as shown in figure 3.
DISCONNECT POWER BEFORE INSTALLING
DESUNA LA ELECTRICIDAD ANTES DE HACER REPARACIONES
WARNING:
1412"
1912"
"X"
TO
FINISHED
FLOOR
ROUGH
WALL
OPENING
178"
334"
"X"
Men
35 3/8"
Women
33 3/8"
Children
23 3/8" - 33 3/8"
Disabled
27 3/8"
step-02_rough opening
10/19/2012 Jay Harnish
STEP 2.
Fig. 2
Begin with a 14-1/2” W x 19-1/2” H
rough wall opening framed on all sides.
Make sure the opening is the correct
distance above the floor. Refer to the
chart below for mounting heights.
1412"
1912"
"X"
TO
FINISHED
FLOOR
ROUGH
WALL
OPENING
178"
334"
"X"
Men
35 3/8"
Women
33 3/8"
Children
23 3/8" - 33 3/8"
Disabled
27 3/8"
step-02_rough opening
10/19/2012 Jay Harnish
14-1/2”
19-1/2”
X
TO
FINISHED
FLOOR
3-3/4”
1-7/8”