TVtoLCD User´s Guide
Technical Specifications
51
7.
Technical Specifications
These values were measured with OSD-Panel attached and without flatpanel and backlight inverter.
-
Supply voltage at 25˚C :
Minimum supply voltage
+ 11,4 V DC
Typical supply voltage
+ 12,0 V DC
Absolute Maximum supply voltage
+ 12.6 V DC
-
Typical Input current at 25
˚
C:
CRT
to
LCD-7- OSD-keypad, input signal SXGA:
680mA
CRT
to
LCD-7- OSD-keypad, power down:
380mA
-
Supply voltage ripple:
100 mV peak to peak 0 – 20 MHz
VGA connector signals :
Sync input voltage low :
0.8 V
Sync input voltage high:
2.4 V
RGB input voltage:
0 – 0.7 V with 75 Ohm external termination
RGB input current:
0 – 5 mA
-
Current Rating of Flatpanel Power supply:
PANEL VCC Steady State 3V / 5V and 12V @ +-5% : 3A
PANEL VCC 5sec. -5% 3V3 @5,6A
PANEL VCC 5sec. -5% 5V @ 5,15A
PANEL VCC 5sec. -2% 12V @ 4A
Note: Output power without any switch or short circuit breaker
-
Current Rating of the output circuits:
12V Output voltage without any switch or short circuit breaker
CN7001: Maximum output current 4A
CN7002: Maximum output current 2A
-
Temperature:
ambient:
0˚C – 60˚C (*1)
non operating:
-10˚C – 85˚C
(*1) The maximum operating temperature is the maximum measurable temperature on any spot on the
module surface. It is the user responsibility to keep this temperature within the above specification.
-
Temperature gradient:
operating:
25˚C per hour
non operating:
40˚C per hour
-
Relative Humidity:
operating:
10% - 90% RH non-condensing
non operating:
5% - 95% RH non-condensing