www.kontron.com
CP3923 User Guide
31
3.5.4.1
Health LED (Green LED)
The CP3923 Switch Board supports a Health LED „H“mounted on the front panel. The following states are possible:
3.5.4.2
Activity LED (Green LED)
The position of this LED „A“ is near the bottom handle beside the health LED. The LED is not used.
3.5.4.3
Management LED (Green LED)
The management LED „M“ indicates link and activity status on the management Ethernet link on the CP-RIO3-923-8C (see
chapter “Rear IO Module” on page 35.). The LED color is green with the following states:
•
Off
link down
•
On
link up but no activity
•
Blinking
link up and activity
3.5.5
Front Panel Switches (not on CP3923-RC)
The handle switch is actuated with the ejector handle of the board. It is used to signal the inserting or impending
extraction of the board.
A reset switch is provided being activated with an adequate tool (e.g. pencil). When the switch is pressed, the board per-
forms a power cycle to all payload devices and resets the PM.
3.5.6
Backplane Connectors
The complete CompactPCI connector configuration comprises two connectors named J1 and J2.
The board supports signaling voltages V(I/O) of either 3.3 V or 5 V. No keying is required on J1 which designates universal
V(I/O).
For accessing the GbE interfaces signals without a rear I/O module, a backplane is required which routes the Ethernet sig-
nals directly to the CPU slots without the need of external cabling. Please contact Kontron if you're looking for such a solu-
tion.
Table 3-8:
Health LED state
LED state
Description
ON
Normal state when board is in operation.
Short Blinking
“Health Error" sensor asserted
Table 3-9:
Activity LED state
LED state
Description
off
Default setting (LED not used)