Power consumption of the CP3923:
• Management only (handle open): <1W
• Idle (no links): 11W
• Maximum (full traffic/load): <20W
1.3.4
Temperature
• Operation from -40° C to +70° C (+85°C for 10 min) according EN50155, convection cooled
• RC version: up to 85°C under continuous operation according to VITA 47 (measured at frame-to-housing contact sur-
face)
• Storage temperature range -50° C to +105° C. For the CP3923-RC, the storage temperature is not compliant to VITA
C4, only to VITA C2.
Required average inlet airflow should be around 400LFM (2 m/s) for the maximum cooling of the non-conduction-cooled
versions. Other thermal limitations may apply and are the responsibility of the system integrator. For more information on
temperature, see chapter “Thermal Considerations” on page 67.
1.3.5
Humidity
The board is designed to meet Bellcore GR63, Section 4.1, resp. VITA 47 (RC version).
• Operating: 93% (non-condensing) at 40°C
• Non-Operating: 5%-95% (non-condensing) at 40°C
1.3.6
Altitude
The board is designed to meet the following requirements:
• Operating: 15000 ft, additional cooling might be required above 6000ft
• Non-Operating: 60000 ft
1.3.7
Vibration
The board is designed to meet the following requirements:
• Standard
• DIN/IEC 60068-2-6
• DIN/IEC 60068-2-64
• VITA 47 (RC version)
• 10Hz to 300Hz, Acceleration: 5 g, Test Cycle: 1 oct./min., Cycle Count: 10/axis, 3 axis
• 20Hz to 500Hz / 500Hz to 2000Hz, Acceleration: 3,5 g RMS, Duration: 30 min/axis
1.3.8
Bump
The board is designed to meet the following requirements:
• Standard
• DIN/IEC 60068-2-29
• VITA 47 (RC version)
• Peak Acceleration: 15 g, Shock Duration: 11 ms half sine, Shock Counts: 500/direction, Recovery Time: 1 s