Thermal Considerations
CP308
Page 6 - 8
ID 1027-4487, Rev. 3.0
P R E L I M I N A R Y
TDP curves
• 100% TDP curve
This load complies with the maximum thermal design power (TDP) indicated in Chap-
ter 5.2 Power Consumption, Table 5-8. 100% TDP can be achieved through the use
of specific tools to heat up the processor, but 100% TDP is unlikely to be reached in
real applications.
• 75% TDP curve
This load represents a "typical" maximum power consumption reached under OS con-
trolled applications. Typically, this load corresponds with 75% of the TDP (see Chapter
5.2 Power Consumption, Table 5-7).
How to read the diagram
Select a specific CPU and choose a specific working point indicated in TDP percentage. For a
given flow rate there is a maximum airflow input temperature (= ambient temperature) provided.
Below this operating point, thermal supervision will not be activated. Above this operating point,
thermal supervision will become active protecting the CPU from thermal destruction. The min-
imum airflow rate provided must not be less than the value specified in the diagram.
Volumetric flow rate
The volumetric flow rate refers to an airflow through a fixed cross-sectional area (i.e. slot width
x depth. The volumetric flow rate is specified in m³/h (cubic-meter-per-hour) or cfm (cubic-feet-
per-minute) respectively.
Conversion: 1 cfm = 1.7 m³/h; 1 m³/h = 0.59 cfm
Airflow
At a given cross-sectional area and a required flow rate, an average, homogeneous airflow
speed can be calculated using the following formula:
Airflow = Volumetric flow rate / area.
The airflow is specified in m/s (meter-per-second) or in fps (feet-per-second) respectively.
Conversion: 1 fps = 0.3048 m/s; 1 m/s = 3.28 fps
The following figures illustrate the operational limits of the CP308 taking into consideration
power consumption vs. ambient air temperature vs. airflow rate. The measurements were
made based on a 4HP slot and with both processor cores enabled.
Содержание CP308
Страница 10: ...Preface CP308 Page x ID 1027 4487 Rev 3 0 P R E L I M I N A R Y This page has been intentionally left blank ...
Страница 14: ...Preface CP308 Page xiv ID 1027 4487 Rev 3 0 P R E L I M I N A R Y This page has been intentionally left blank ...
Страница 22: ...Preface CP308 Page xxii ID 1027 4487 Rev 3 0 P R E L I M I N A R Y This page has been intentionally left blank ...
Страница 23: ...CP308 Introduction ID 1027 4487 Rev 3 0 Page 1 1 Introduction Chapter 1 1 P R E L I M I N A R Y ...
Страница 67: ...CP308 Installation ID 1027 4487 Rev 3 0 Page 3 1 Installation Chapter 1 3 P R E L I M I N A R Y ...
Страница 81: ...CP308 Configuration ID 1027 4487 Rev 3 0 Page 4 1 Configuration Chapter 1 4 P R E L I M I N A R Y ...
Страница 102: ...Configuration CP308 This page has been intentionally left blank Page 4 22 ID 1027 4487 Rev 3 0 P R E L I M I N A R Y ...
Страница 103: ...CP308 Power Considerations ID 1027 4487 Rev 3 0 Page 5 1 Power Considerations Chapter 1 5 P R E L I M I N A R Y ...
Страница 111: ...CP308 Thermal Considerations ID 1027 4487 Rev 3 0 Page 6 1 Thermal Considerations Chapter 1 6 P R E L I M I N A R Y ...
Страница 121: ...ID 1027 4487 Rev 3 0 Page A 1 CP308 CP308 HDD CUSTOMER SPECIFIC P R E L I M I N A R Y CP308 HDD Appendix 1 A ...
Страница 135: ...CP308 CP308 MEDIA ID 1027 4487 Rev 3 0 Page B 1 CP308 MEDIA Appendix 1 B P R E L I M I N A R Y ...
Страница 136: ...CP308 MEDIA CP308 Page B 2 ID 1027 4487 Rev 3 0 P R E L I M I N A R Y This page has been intentionally left blank ...
Страница 154: ...CP308 MEDIA CP308 Page B 20 ID 1027 4487 Rev 3 0 P R E L I M I N A R Y This page has been intentionally left blank ...
Страница 155: ...ID 1027 4487 Rev 3 0 Page C 1 CP308 CP RIO3 04 Rear I O CUSTOMER SPECIFIC P R E L I M I N A R Y CP RIO3 04 Appendix 1 C ...