Hardware Installation
88
AM4904 User Guide
www.kontron.com
2. Ensure that the module is properly configured for operation in accordance with the application require-
ments before installation.
3. Ensure that the module handle is in the “Unlocked” position.
4. Using the front panel as a grip, carefully insert the module into the slot designated by the application
requirements until it makes contact with the backplane connector.
5. Apply pressure to the front panel until the module is properly seated in the backplane connector. This
may require a considerable amount of force. Apply pressure only to the front panel, not the module
handle. During seating in the connector, there is a noticeable “snapping” of the board into the connec-
tor. When the board is seated it should be flush with the system front panel.
In the case of a running system, the following occurs:
• The BLUE HS LED turns on.
When the module is seated, the module management power is applied and the BLUE HS LED turns
on. (No payload power is applied at this time).
• Connect all external interfacing cables to the module as required and ensure that they are properly
secured.
• Push the module handle in the “Locked” position. When the module handle is in the “Locked” po-
sition, the module is locked and the hot swap switch is actuated.
In the case of a running system, the following occurs:
• The BLUE HS LED turns off.
The power module now enables the payload power for the MCH.
• The MCH module is now operating.
4.2.2 Hot Swap Extraction
To extract the MCH module proceed as follows:
1. Ensure that the safety requirements indicated in section 4.1 are observed.
2. Pull the module handle in the “Hot Swap” position.
When the module handle is in the “Hot Swap” position, the extraction process of the module is initiated and
the following occurs:
• The BLUE HS LED displays short blinks. When the power module IPMI controller receives the handle
opened event, it sends a command to the MCMC with a request to perform short blinks of the BLUE
HS LED.
This indicates that the MCH is waiting to be deactivated.
Once the MCH receives the permission to continue the deactivation, all used ports are disabled.
• The BLUE HS LED turns on.
The Intelligent Platform Management Controller on the power module disables the module's pay-
load power and the BLUE HS LED is turned on.
Now the module is ready to be safely extracted.
WARNING
Care must be taken when applying the procedures below to ensure that
neither the AM4904 nor other system boards are physically damaged by
the application of these procedures.
Содержание AM4904
Страница 19: ...1KTC5520 EATX Chapter 1 Introduction www kontron com...
Страница 24: ...6KTC5520 EATX Chapter 2 Functional Description www kontron com...
Страница 65: ...47KTC5520 EATX Chapter 3 Operating the Unit www kontron com...
Страница 104: ...85KTC5520 EATX Chapter 4 Hardware Installation www kontron com...
Страница 109: ...90KTC5520 EATX Chapter 5 Power Considerations www kontron com...
Страница 113: ...Chapter 6 Thermal Considerations www kontron com...
Страница 121: ...1 Appendix A CM Configuration Options www kontron com...
Страница 128: ...1 Appendix B Getting Help www kontron com...
Страница 131: ...1KTC5520 EATX Appendix C Glossary www kontron com...