background image

Preface

ix

AM4301 User's Guide

Regulatory Compliance Statements

FCC Compliance Statement for Class B Devices

This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generated, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions 
may cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment 
off and on, the user is encouraged to try to correct the interference by one or more of the following 
measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

• Consult the dealer or an experience radio/TV technician for help. 

UL Certification

This product bears the combined UL Recognized Component Mark for Canada and U.S. It indicates 
investigations to the UL Standard for Safety of Information Technology Equipment, Including 
Electrical Business Equipment. It is destinated to be used in end-product equipment where the 
acceptability of the combination is determined by Underwriters Laboratories Inc.

CE Certification

The product described in this user's guide was tested in a representative system and is found to be 
compliant with the CE marking requirements. For computer systems to remain CE compliant, only 
CE-compliant parts may be used. Maintaining CE compliance also requires proper cable and cabling 
techniques. Although Kontron offers accessories, the customer must ensure that these products 
are installed with proper shielding to maintain CE compliance. Kontron does not offer engineering 
services for designing cabling systems. In addition, Kontron will not retest or recertify systems or 
components that have been reconfigured by customers.

WARNING

This is a Class B product. If not installed in a properly shielded enclosure and used in 
accordance with this User's Guide, this product may cause radio interference in 
which case users may need to take additional measures at their own expense.

Содержание AM4301

Страница 1: ...AM4301 User s Guide Document Revision 1 2 May 2009...

Страница 2: ...tion and products protected by copyrights or patents and does not convey any license under the patent rights of Kontron nor the rights of others Kontron is a registered trademark of Kontron All tradem...

Страница 3: ...1 1 Product Overview 1 1 2 What s Included 1 1 3 Board Specifications 2 1 4 Compliance 3 1 5 Hot Swap Capability 3 2 Board Features 4 2 1 Block Diagram 4 2 1 1 PCI Tree 4 2 2 Ethernet Interfaces 5 2...

Страница 4: ...terconnectivity 13 3 1 1 Onboard Connectors and Headers 13 3 2 Board Hot Swap and Installation 13 3 2 1 Installing an AMC 13 3 2 2 Removing an AMC 14 A Connector Pinouts A 1 A 1 CONNECTORS AND HEADERS...

Страница 5: ...horized electronics service personnel should access the interior of the computer The power supplies produce high voltages and energy hazards which can cause bodily harm Use extreme caution when instal...

Страница 6: ...nt s antistatic packing material until you are ready to install the component in a computer Just before unwrapping the antistatic packaging be sure you are at an ESD workstation or grounded This will...

Страница 7: ...esponsibility as far as patents or other rights of third parties are concerned The following is a summary of chapter contents Chapter 1 Product Description Chapter 2 Onboard Features Chapter 3 Install...

Страница 8: ...npacking Follow these recommendations while unpacking Remove all items from the box If any items listed on the purchase order are missing notify Kontron customer service immediately Inspect the produc...

Страница 9: ...Preface viii AM4301 User s Guide Storing Boards Electronic boards are sensitive devices Do not handle or store device near strong electrostatic electromagnetic magnetic or radioactive fields...

Страница 10: ...an experience radio TV technician for help UL Certification This product bears the combined UL Recognized Component Mark for Canada and U S It indicates investigations to the UL Standard for Safety o...

Страница 11: ...ost of purchase if appropriate In the event of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to Kontron and the remaining part of the original guar...

Страница 12: ...PCI E x4 link and supports remote management via IPMI v1 5 As a hot swappable field replaceable unit FRU the AM4301 also follows the same stringent carrier grade RASM feature set namely Reliability A...

Страница 13: ...ard temperature sensor power failure Mechanical 181 5 x 75 x 18 96 mm Single width mid size 181 5 x 75 x 30 16 mm Single width Full height Power Requirements Management power is less than 150mA peak a...

Страница 14: ...TCA core specification AMC 0 R2 0 AMC 1 R1 0 1 5 Hot Swap Capability The AM4301 supports Full Hot Swap capability as per PICMG3 0R1 0 It can be removed from or installed in the system while it is on...

Страница 15: ...N GIGABIT B A 82571 EB TWIN GIGABIT B A PEX8517 PCIe Switch PCIe X4 PCIe X4 PCIe X8 CLK3 DB800 EEPROM EEPROM QUAD RJ45 2 Board Features 2 1 Block Diagram 2 1 1 PCI Tree This diagram represent how the...

Страница 16: ...ogrammed by another microcontroller named FWUM FirmWare Update Manager The FWUM keeps the last two copies of the MMC firmware in dedicated flash memories It act as a watchdog to the MMC and can rollba...

Страница 17: ...the payload power and the restart of the MMC will not affect the payload and will restore the previous Module Hot Swap state The watchdog timeout expires after six seconds if strobes are not generated...

Страница 18: ...gent that verify FRU Data validity N ModuleHotSwap AMC HS State N IPMBL State Operational state of IPMB L N Storage Err Management sub system health non volatile memory error N Board 3 3V 3 3 V X Boar...

Страница 19: ...E lane 0 detection N PexLaneGood 1 PCIE lane 1 detection N PexLaneGood 2 PCIE lane 2 detection N PexLaneGood 3 PCIE lane 3 detection N PexLaneGood 4 PCIE lane 4 detection N PexLaneGood 5 PCIE lane 5 d...

Страница 20: ...the firmware as part of Module data 2 4 4 E Keying E Keying has been defined in the AMC 0 R1 0 Specification to prevent module damage prevent misoperation and verify bay connection compatibility The...

Страница 21: ...computer to exchange with the FirmWare Upgrade Manager FWUM in order to upgrade to FWUM or the MMC firmware Then this tool doesn t need the KCS driver to run over the Carrier AMC it doesn t use the I...

Страница 22: ...C or higher level software can reject the request to move to the M6 state If this occurs the AMC Carrier will returns the Hot Swap LED to a solid off condition indicating that the AMC has returned to...

Страница 23: ...h LED2 The green LED indicates that the AMC is working properly The amber LED indicates that the AMC is in fault 2 5 2 Out of service LED1 When this LED is off it indicates that the board is working p...

Страница 24: ...t and extract the board from its enclosure 3 2 1 Installing an AMC To install an AMC 1 Remove the AMC filler panel 2 Carefully engage the AMC into the card guide Push the AMC until it fully mate with...

Страница 25: ...2 2 Removing an AMC To remove an AMC 1 Open the AMC handle 2 The blue LED will start blinking wait until it is solid blue 3 Extract the AMC by pulling it out with the handle Note Ensure that your OS i...

Страница 26: ...D5 B96 TxD9 B139 TxD16 N C B12 RxD0 B54 RxD5 B97 TxD9 B140 GND B13 GND B55 GND B98 GND B141 RxD17 B14 TxD0 B56 IPMI_CLK B99 RxD10 B142 RxD17 B15 TxD0 B57 12V B100 RxD10 B143 GND B16 GND B58 GND B101 G...

Страница 27: ...D20 B35 TxD3 B77 CLKB B120 TxD13 N C B163 TxD20 B36 TxD3 B78 CLKB B121 TxD13 N C B164 GND B37 GND B79 GND B122 GND B165 TCLK B38 RxD3 B80 REFCLK B123 RxD14 B166 TMS B39 RxD3 B81 REFCLK B124 RxD14 B167...

Страница 28: ...Tel 49 0 8341 803 333 Fax 450 437 8053 Fax 49 0 8341 803 339 If you have any questions about Kontron our products or services visit our Web site at www kontron com You also can contact us by E mail a...

Страница 29: ...ician will instruct you on the return procedure if the problem cannot be solved over the telephone 4 Make sure you receive an RMA from our Technical Support before returning any merchandise Fax 1 Make...

Страница 30: ...oice s associated with the item s in question Ensure that the unit is properly packed Pack it in a rigid cardboard box Clearly write or mark the RMA number on the outside of the package you are return...

Страница 31: ...______ City __________________________ Province State _________________________ Country __________________________ Postal Zip Code _________________________ Phone Number __________________________ Ext...