2-8
104-422/485-2I User’s Guide
Card Address jumpers are marked A5-A9. The following table lists jumpers name vs. the address
line controlled and the relative weights of each.
Table 2-2. Card Base Address Setup
In order to read the address jumper setup, assign a binary "1" to jumpers that are OFF and a
binary "0" to the jumpers that are ON. For example, as illustrated in the following table, address
selection corresponds to binary 11 000x xxxx (hex 300). The "x xxxx" represents address lines
A4 through A0 used on the card to select individual registers. See Chapter 5, Programming in
this manual.
Hex Range
Usage
300-31F
Prototype Card
360-36F
Reserved
378-37F
Parallel Printer Port 1
380-38F
SDLC or Binary Synchronous Comm’n 2
3A0-3AF
Binary Synchronous Comm’n 1
3B0-3BF
Monochrome Display/Printer
3C0-3CE
Local Area Network
3D0-3DF
Color/Graphic Monitor
3F0-3F7
Floppy Diskette Controller
3F8-3FF
Asynchronous Comm’n (Primary)
Card Address Settings
1st Digit
2nd Digit
3rd
Digit
Jumper Name
A9
A8
A7
A6
A5
Address Line Controlled
A9
A8
A7
A6
A5
Decimal Weight
512
256
128
64
32
Hexadecimal Weight
200
100
80
40
20
Содержание 104-422-2I
Страница 1: ...www kontron com 104 422 485 2I User s Guide Manual PN 931 0071 00 A November 2002...
Страница 6: ...vi 104 422 485 2I User s Guide This page intentionally left blank...
Страница 10: ...x 104 422 485 2I User s Guide This page intentionally left blank...
Страница 12: ...xii 104 422 485 2I User s Guide This page intentionally left blank...
Страница 20: ...xx 104 422 485 2I User s Guide This page intentionally left blank...
Страница 44: ...Chapter 4 Connector Pin Assignments Contents Overview 4 3 Connector Pin Assignments 4 3...