www.ks-power.de/en
|
12
MANUAL START
MANUAL START
Do not connect any devices before you start the engine!
1. Connect the positive terminal of the battery.
2. Turn the motor safety switch (Fig. 1) to ON position.
3. Pull the starter handle until you feel resistance.
4. Remove the rubber plug on the top cover of the generator, which
is under decompressor lever (fig. 2), push the decompressor at the
top of cylinder head to reduce pressure in the cylinder and relief
extension.
5. Vigorously pull starter handle and start the engine.
6. Do not let a sharp return to starter motor. To avoid starter damage,
return it to the original position carefully.
7. After three minutes of the generator work, switch machine
protection (Emergency switch) in the upper position ON.
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD
BE MET:
BE MET:
1. During commissioning, do not connect power consumers, the power of which exceeds 50% of the
nominal (operating) power of the device.
2. After the first 20 operating hours, be sure to change the oil. It is better to drain oil while the engine is still
hot after operation to ensure quick and complete oil draining.
3. Check and clean the air filter and fuel filter.
Fig.1
Fig.2
ELECTRIC START
ELECTRIC START
1. Do not connect any devices before you start the engine!
2. Connect the positive terminal of the battery.
3. Turn the motor safety switch (Fig. 1) to ON position.
4. Set the key to ON position.
5. Turn the key clockwise to START position.
6. After the engine launch, release the key, and it will automatically return to ON position.
7. If the engine doesn’t start after keeping the key in START position for 10 seconds, wait 15 seconds before
trying start again. The battery can discharge after continuous work of launch engine system. Leave the key
in ON the position during work.
8. After three minutes of the generator work, switch machine protection (Emergency switch) in the upper
position ON.
If engine does not start after three or four attempts, it
may mean that the fuel system has some air inside. Re-
move the air from the fuel system (drain the diesel fuel,
with the fuel there will be excess of air).
IMPORTANT!
Do not let the simultaneous connection of two or more
devices. Start of many devices requires large power
capacity
ATTENTION - DANGER!
Devices are to be connected in turns, according to its maximum allowed power. Do not con-
nect the consumers in first 1-2 minutes after the generator start. Do not stop the generator,
if there are any devices connected. This may result to generator breakdown.
Before turning the generator on, verify that the connected devices are in working order. If the connected
device suddenly stops running – turn the power off by means of an emergency switch, disconnect the
device and check it.