Cause
Solution
A-Insufficient oil in pump
Check oil level in reservoir
B-Air in oil
Check oil level in reservoir
C-Excessive pump inlet vacuum
Check pump inlet hose for blockage or kinks
D-Blocked hydraulic lines
Flush and clean the splitter hydraulic system
E-Blocked control valve
Flush and clean the splitter hydraulic system
F-Low control valve setting
Adjust control valve with a pressure gauge
G-High control valve setting
Adjust control valve with a pressure gauge
H-Damaged control valve
Return control valve for authorized repair
I-Internal control valve leak
Return control valve for authorized repair
J-Internal cylinder leak
Return cylinder for authorized repair
K-Internally damaged cylinder
Return cylinder for authorized repair
L-Engine control out of adjustment
Adjust idle control nuts
M-Engine is loaded during idle down mode
Use shorter log length to allow engine to speed up before
contact.
REGULAR MAINTENANCE CHECKLIST
9
PROCEDURE
Every start
or 20 hours
Before each use
Every 5 hours
Each 3 months or after 50 working
hrs
Each 6 months or after 100 working
hrs
Every year or after 150 working hrs
Motor oil
Check
Replace
First time 5
hours
Hydraulic oil
Check
Replace
Air filter
Check
Clean out
Replace
Check general equipment
Check
Grease surfase of slide rail
Lubricate
Check belts
Check
Grease Rack and pinion
Lubricate
Clean engine exterior and
cooling
Clean out
Spark plug
Gap check and
control
Replace
Comply with the instructions in this manual! You can find an updated list of service center on the website
of exclusive importer:
www.ks-power.de/en
www.ks-power.de/en
|
10
Содержание KS 27THG 65/55
Страница 1: ...Gasolline Log Splitter Please read this manual carefully before use Owner s Manual KS 27THG 65 55 EN ...
Страница 6: ...P www ks power de en 5 ...
Страница 14: ......