background image

E-6

21. Install the Punch kit cover. (TP screw M3x6: 3 pcs.)

Note:

When installing the Punch kit cover, be careful not
to get the wire bundles caught in it.

22. Pull out the paper nipped by the interlock and

close the finisher’s front door. 

Adjusting PI-502 centering

1. Preliminary preparations before adjustment

(1) Place paper in the upper and lower trays of the

PI-502, and make sample copies using the
cover sheet in Punch mode. Check that the
punching hole is within the sensor area when
the hole is punched.
(For upper and lower trays)
* See the figure for item 20 on page E-5.

(2) If there is a gap, execute the next page proce-

dure to adjust it.

2. Adjustment procedures

Step

1. Release the hook and remove the adjustment

cover of the side guide board/back.

15KJIXE023SA

T

P

 scre

w

M

3

x6

P

unch kit cover

15KNIXE012SA

Adjust

m

ent cover

Hook

Side guide board
/back

2. For the lower tray, remove the 2 side guide

board/back mounting screws and slide it to the
right to remove the side guide board/back.

3. Loosen the 2 adjustment screws on the side

guide board/back, and slide the side guide
board/2 to twice the distance of the punch hole
gap. (Example: if holes are centered 1.5mm to
the back, slide the board back 3mm.) 
Gradation: 2mm.

4. Tighten the 2 adjustment screws securely to

fix side guide board/2.

5. Install the side guide board/back in the lower

tray.

Note:

When tightening the 2 mounting screws, make
sure that screw torque doesn’t exceed 5kg • cm.

6. Place paper in the tray and adjust the side

guides. Make sure that the side guide board/
back is parallel to the paper.

7. Repeat steps 2 to 6 until punch hole centering

error is eliminated.

8. Install the adjustment cover on the side guide

board/back.

Step

15KNIXE013SA

Side guide board

/back

M

ounting

scre

w

s

15KNIXE014SA

Adjust

m

ent

scre

w

s

Side guide board/2

Содержание PK-511

Страница 1: ...support 1 into the back side and insert two into the front side Insert the two of the control board support 2 into the central area of the front side No Name Shape Q ty 1 Punch Kit 15KJIXC001SA 1 2 P...

Страница 2: ...hole as shown in the figure 7 Temporarily tighten the screw TP screw M3x6 1 pc on the back side of the finisher Position the sensor on the sensor assembly wire bundle with the projection then fasten...

Страница 3: ...and close the conveyance guide plate 1 once so that the PET at the entrance of the punch kit return to normal position 3 Connect the two Punch kit connectors to the Punch kit and attach the wire bund...

Страница 4: ...e outlet and turn ON the Main power switch 2 Enter Service mode Note Refer to procedures in the Service Manual to enter into the Service Mode 3 Service Mode menu screen Touch System Setting 4 Touch So...

Страница 5: ...n When PI 502 is installed to the finisher 1 Make sample copies from the PI 502 in Punch mode 2 Using the paper sample check the hole posi tion gap by folding the paper in half 3 If hole position gap...

Страница 6: ...KNIXE012SA Adjustment cover Hook Side guide board back 2 For the lower tray remove the 2 side guide board back mounting screws and slide it to the right to remove the side guide board back 3 Loosen th...

Страница 7: ...on is not appro priate use the numerical keys on the screen to enter adjusting values appropriate val ues and touch SET Setting range 50 to 50 1 step 0 1mm 8 Make another sample copy 9 Repeat steps 5...

Страница 8: ...B Top and bottom center gap 80 0 5 Top and bottom B dimension 1 2 1 Step 1 Punch Adjustment Menu screen Touch Vertical Position Adj 2 Select the paper size to be adjusted 3 Touch COPY to display the...

Отзывы: