FS-601 Field Service Ver2.0 Sep. 2004
Trouble code
4-9
IV
T
rou
b
lsh
oot
in
g
2.3
Solution
2.3.1
C0B00:Transport System Drive malfunctions
A. Detection timing
B. Action
Malfunction code
Description
C0B00
The Folding Roller Home Position Sensor (PI12-FN) is not unblocked even after the
lapse of a given period of time after the Folding Roller has started moving from its
home position.
The Folding Roller Home Position Sensor (PI12-FN) is not blocked even after the
lapse of a given period of time after the Folding Roller has started moving from a
position not the home position.
Relevant electrical parts
Folding Roller Home Position Sensor (PI12-FN)
Transport Motor (M1-FN)
Finisher Control Board (PWB-A FN)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Check the motor connectors for proper
connection, and correct as necessary.
-
-
2
Check the connector of motor for proper
drive coupling, and correct as neces-
sary.
-
-
3
PI12-FN I/O, sensor check
PWB-A FN CN16 FN-9
G-3
4
M1-FN operation check when the Power
Switch is turned OFF and ON.
-
A-9
5
PWB-A FN replacement
-
E-6
Содержание FS-601
Страница 1: ...SERVICE MANUAL 2004 09 Ver 2 0 FS 601 THEORY OF OPERATION ...
Страница 2: ......
Страница 4: ......
Страница 10: ...Product specification FS 601 Theory of Operation Ver2 0 Sep 2004 1 4 I Outline Blank page ...
Страница 13: ...FS 601 Theory of Operation Ver2 0 Sep 2004 Paper path 2 3 II Composition Operation 3 Paper path ...
Страница 36: ...Mechanical operations FS 601 Theory of Operation Ver2 0 Sep 2004 2 26 II Composition Operation Blank page ...
Страница 37: ...SERVICE MANUAL 2004 09 Ver 2 0 FIELD SERVICE FS 601 ...
Страница 38: ......
Страница 40: ......
Страница 70: ...Other FS 601 Field Service Ver2 0 Sep 2004 2 22 I General II Maintenance Blank page ...
Страница 88: ...Board switch FS 601 Field Service Ver2 0 Sep 2004 3 18 III Adjustment Setting Blank page ...
Страница 112: ...Trouble code FS 601 Field Service Ver2 0 Sep 2004 4 24 IV Troublshoot ing Blank page ...