Trouble code
FS-601 Field Service Ver2.0 Sep. 2004
4-22
IV
T
rou
b
lsh
oot
in
g
2.3.12
C0BA0:Elevate Mechanism malfunctions
A. Detection timing
B. Action
(1) Upper Limit Sensor
(2) Finisher Control Board
Malfunction code
Description
C0BA0
The Exit Tray Home Position Sensor (PI9-FN) is not blocked even after the lapse of
a given period of time after the tray has started moving up.
An encoder clock input is not detected within a given period of time during opera-
tion of the tray.
Relevant electrical parts
Shift Upper Limit Sensor (PI15-FN)
Finisher Control Board (PWB-A FN)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Check the sensor connectors for proper
connection, and correct as necessary.
-
-
2
PI15-FN I/O, sensor check
PWB-A FN CN15 FN-12
G-8
3
PWB-A FN replacement
-
E-6
Relevant electrical parts
Exit Tray Home Position Sensor (PI9-FN)
Shift Motor Clock Sensor (PI17-FN)
Shift Motor (M6-FN)
Finisher Control Board (PWB-A FN)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical compo-
nents)
1
Check the motor and sensor connectors
for proper connection, and correct as
necessary.
-
-
2
Check the connector of motor for proper
drive coupling, and correct as neces-
sary.
-
-
3
PI9-FN I/O sensor check
PWB-A FN CN5 FN-12
E-8
4
PI17-FN I/O sensor check
PWB-A FN CN15 FN-6
G-8
5
M6-FN operation check when the Power
Switch is turned OFF and ON.
PWB-A FN CN6 FN-1,2
A-4
6
PWB-A FN replacement
-
E-6
Содержание FS-601
Страница 1: ...SERVICE MANUAL 2004 09 Ver 2 0 FS 601 THEORY OF OPERATION ...
Страница 2: ......
Страница 4: ......
Страница 10: ...Product specification FS 601 Theory of Operation Ver2 0 Sep 2004 1 4 I Outline Blank page ...
Страница 13: ...FS 601 Theory of Operation Ver2 0 Sep 2004 Paper path 2 3 II Composition Operation 3 Paper path ...
Страница 36: ...Mechanical operations FS 601 Theory of Operation Ver2 0 Sep 2004 2 26 II Composition Operation Blank page ...
Страница 37: ...SERVICE MANUAL 2004 09 Ver 2 0 FIELD SERVICE FS 601 ...
Страница 38: ......
Страница 40: ......
Страница 70: ...Other FS 601 Field Service Ver2 0 Sep 2004 2 22 I General II Maintenance Blank page ...
Страница 88: ...Board switch FS 601 Field Service Ver2 0 Sep 2004 3 18 III Adjustment Setting Blank page ...
Страница 112: ...Trouble code FS 601 Field Service Ver2 0 Sep 2004 4 24 IV Troublshoot ing Blank page ...