E-16
6. Obtain the difference between the deviation of
the chart and the deviation of the sample.
Difference of the deviation = Y - X
Specifications: 0 ± 2.0 mm
* If the difference of the deviation does not fall
within the specified range, perform the following
adjustment.
7. Loosen the mounting screw on the right hinge
viewed from the front.
8. When the difference of the deviation is + (plus),
turn the adjustment screw located at the back of
the reverse automatic document feeder counter-
clockwise to adjust.
Note:
• Look at the guide lines when making the adjust-
ment.
• When turning the screw, be sure not to raise the
reverse automatic document feeder until in an
upright position.
* To prevent the adjustment screw breakage, be
sure to follow the above instructions.
9. When the difference of the deviation is - (minus),
turn the adjustment screw located at the back of
the reverse automatic document feeder clockwise
to adjust.
Note:
• Look at the guide lines when making the adjust-
ment.
• When turning the screw, be sure not to raise the
reverse automatic document feeder until in an
upright position.
*
To prevent the adjustment screw breakage, be
sure to follow the above instructions.
10. After the adjustment is completed, tighten the
mounting screw on right side hinge securely with
screwdriver.