27
6. CARE, MAINTENANCE AND REPLACEMENT OF WEARING PARTS
PARALLELISM AND G-MEASUREMENT OF THE
MOULDBOARDS
Check the working angle of the mouldboard. The normal position is measured on the rear
plough body between the extended inside line of the landside, horizontally out against the
outermost hole in the mouldboard, see measurement
G
. Adjust the mouldboard stay if
necessary.
AX
Mouldboard normal measurement G
= 580 mm
XLD
Mouldboard normal measurement G
= 670 mm
AH
Mouldboard normal measurement G
= 625 mm
FC
Mouldboard normal measurement G
= 550 mm
AS
Measurement to the outer end of the bottom slat = 635 mm
Measurement to the outer end of the top slat
= 505 mm
XSD Measurement to the outer end of the bottom slat = 644 mm
Measurement to the outer end of the top slat
= 400 mm
Measure from the now adjusted rear, mouldboard forward and adjust the mouldboard stays
if necessary, to the point to point clearance 900 mm
A= B
.
A
B