Replacing the Sensor Unit
Procedure
1
Disconnect the data and power cables in the junction box.
2
Remove the Sensor Unit from the mounting bracket.
3
Connect the data and power cables of the replacement Sensor Unit.
4
Lift the replacement Sensor Unit and hook it onto the mounting bracket.
5
Refasten the Sensor Unit.
6
Remember to refasten the safety wire, if you have used one.
Related topics
• Refer to the
XPR Installation Manual
for Sensor Unit installation.
Configuring a replacement Sensor Unit
If the IP address of the replacement Sensor Unit is identical to that on the replaced Sensor
Unit, it will be added to the configuration automatically. If not, you must configure the
replacement Sensor Unit. Refer to the
Selecting Sensor Units for operation
section in the
XPR Installation Manual
to configure the replacement unit.
If the IP address of the replacement Sensor Unit conflicts with an existing Sensor
Unit’s IP address, you must change IP address of the replacement Sensor Unit. Refer
to the
Changing the Sensor Unit IP address
section in the
XPR Installation Manual
to
configure the replacement unit.
Replacing cables or connectors
It is recommended to inspect the cables and connectors for possible damage from time
to time. If the connectors are damaged, the connectors and cables must be replaced.
The Sensor Unit must be sent to Kongsberg Seatex AS for inspection and servicing.
Alternatively, service personnel can be sent to inspect the XPR system on-site.
Related topics
• Refer to the
XPR Installation Manual
for cable details.
Changing the fuse in the Processing Unit
If the Processing Unit does not receive power,
it could be because of a blown fuse.
Note
Fuses shall only be replaced with the same type
and rating.
XPR-D-User/1.0