With filter cover
Filter cover removed
Filter cover and filter
Cleaning of Sensor Unit cover
Use a moist cloth to clean the Sensor Unit cover when necessary. It is important to keep
the Sensor Unit plastic cover clean to maintain a fully operational and accurate system.
Inspecting the Remote interface cabinet
Maintenance must be performed at regular intervals depending on use and ambient
conditions. At least once a year.
Procedure
1
Check the door hinges for ease of movement. Spray with a suitable water-free
lubricant.
2
Check the door lock for ease of movement. Spray with a suitable water-free
lubricant.
3
Check the gasket in the contact edge area. Replace the gasket if it is damaged.
Common talcum, vaseline or wax can be used to prevent damage due to the gasket
freezing because of low temperatures.
4
Check all components and surfaces for external damage.
5
Check for traces of corrosion.
XPR-D-User/1.0