94
394149/D
List of EK80 cables
A set of cables is required to connect the EK80 units to each other, and to the relevant
power source(s). Additional cables are required to connect the EK80 to peripheral
devices.
Cables identified with an asterisk (*) are system or commercial cables. These cables are
provided with the EK80 delivery or the relevant item. One transducer cable (marked
with a dual asterisk (**)) is provided with each transducer.
Topside cables
Cable
Type
From/To
Minimum requirements
C1*
AC power cable
From display to AC power outlet
2 x 1.5 mm
2
+ 1.5 mm
2
Ground
C2*
AC power cable
From Processor Unit to AC
power outlet
2 x 1.5 mm
2
+ 1.5 mm
2
Ground
C3
Ground cable
From display to vessel ground
1 x 6 mm
2
C4
Ground cable
From Processor Unit to vessel
ground
1 x 6 mm
2
Video cable
From Processor Unit to display
C5*
This is a commercial cable. The display cable is often physically attached to the display,
and terminated in the “computer end” with a male connector. If the cable is not attached,
it is normally provided with the display.
C6*
Computer cable
From Processor Unit to keyboard
C7*
Computer cable
From Processor Unit to mouse
(or another similar device)
C8
Ethernet cable
From Processor Unit to Wide
Band Transceiver (WBT)
CAT5-E STP (Shielded Twisted
Pair)
C9
Ethernet cable
From Processor Unit to local
area network (LAN)
CAT5-E STP (Shielded Twisted
Pair)
C10
Serial cable
From Processor Unit to external
device(s)
2 x 4 x 0.5 mm
2
C11–14
Not used
Sonar room cables
Cable
Type
From/To
Minimum requirements
C8
Ethernet cable
From Processor Unit to Wide
Band Transceiver (WBT)
CAT5-E STP (Shielded Twisted
Pair)
C15
Ground cable
From Wide Band Transceiver
(WBT) to vessel ground
1 x 6 mm
2
Simrad EK80 Installation Manual
Содержание Simrad EK80
Страница 1: ...kongsberg com simrad Simrad EK80 INSTALLATION MANUAL ...
Страница 2: ......
Страница 12: ...10 394149 D Simrad EK80 ...
Страница 223: ...394149 D 221 6 Start the installation by selecting Next 7 Select Finish to close the wizard Setting to work ...
Страница 313: ...394149 D 311 Drawing file ...
Страница 314: ...312 394149 D Simrad EK80 Installation Manual ...
Страница 317: ...394149 D 315 Drawing file ...
Страница 318: ...316 394149 D Simrad EK80 Installation Manual ...
Страница 320: ...318 394149 D 201575 Transducer connector assembly and wiring Simrad EK80 Installation Manual ...
Страница 352: ... 2020 Kongsberg Maritime ISBN 978 82 8066 182 1 ...
Страница 353: ......
Страница 354: ...Installation Manual Simrad EK80 ...