Refitting the Leistritz pump to the Power Pack unit
1.
Mount the pump to the bell housing [7] with Loctite 577 and 574 applied to the threads and
between the connecting flanges respectively.
2.
Mount the SAE flange [5] to the pump unit and replace the oil tank cover.
3.
Replace the coupling [8] on the pump shaft. The coupling shall be mounted so that the
distance to the bell house to the bottom of the coupling is equal to the distance from the
motor flange to the lowest point on the motor side coupling with a 2 mm clearance added.
4.
Fasten the coupling by tightening the set screw.
5.
Insert a new flexible coupling.
6.
Align the couplings and lower the motor vertically on to the bell house.
7.
Fasten the motor, oil tank cover, SAE flanges and pipes [1] leading to the actuator and
electrical cables.
8.
Turn the selector switch on the motor controller to position 2 “REMOTE CONTROL”.
Note!
If necessary, perform the venting procedure as described in chapter