Optional step: If you are running the system for the first time, verify that the
Runtime
Settings
are set correctly. The Runtime settings specify how the Synchronizing
Unit will determine when each echo sounder is ready to advance to the next group
(see figure
on page 30).
An echo sounder that provides
ready to transmit
feedback signal should normally
have the operating mode set to
External input
. Otherwise, check that the calculation
parameters are set according to type of echo sounder.
If
Calculated
mode is selected, then the multiplication factor should be 0% if
single beam echo sounder. This will cause the Synchronizing Unit to wait at least
the duration of the two-way roundtrip time (travel time) at the current depth.
A multibeam system will have a wider swath, and consequently the roundtrip
time will increase depending upon swath angle. When
Calculated
is selected, the
resulting duration for each parameter is computed and presented to operator to allow
verification at current depth (see figure
on page 29. If
Fixed period
mode is used, then enter the desired period. This period will be fixed regardless
of depth.
Figure 23