Appendix B Basic cable requirements
• Cables having a copper sheath or braiding must be installed in such a way that
galvanic corrosion by contact with other metals is prevented.
• For service purpose of the system, all cables should be allocated spare conductor pairs.
Also, space within the vessel should be set aside for the installation of extra cables.
Radio Frequency interference
All cables that are to be permanently installed within 9 m (30 ft) of any source of Radio
Frequency (RF) interference such as a transmitter aerial system or radio transmitters,
must, unless shielded by a metal deck or bulkhead, be adequately screened by sheathing,
braiding or other suitable material. In such a situation flexible cables should be screened
wherever possible.
It is important that cables, other than those supplying services to the equipment installed
in a radio room, are not installed through a radio room, high power switch gear or other
potential sources of interference. Cables which pass through a radio room must be
screened by a continuous metal conduit or trunking. These cables must be bonded to the
screening of the radio room at its points of entry and exit.
Physical protection
Cables exposed to the risk of physical damage must be enclosed in a steel conduit
or protected by a metal casing unless the cable's covering (e.g. armour or sheath) is
sufficient to protect it from the damage risk.
Cables exposed to mechanical damage (for example in holds, storage-spaces and
cargo-spaces) must be protected by a suitable casing or conduit, even when armoured, if
the cable covering does not guarantee sufficient protection for the cables.
Metallic materials used for the physical protection of cables must be suitably protected
against corrosion.
Grounding
All metallic cable coverings (armour, metallic sheathing etc.) must be electrically
connected to the vessel's hull at both ends except in the case of final sub-circuits where
they should be connected at the supply end only.
Grounding connections should be made using a conductor which has a cross-sectional
area appropriate for the current rating of the cable, or with a metal clamp which grips
the metallic covering of the cable and is bonded to the hull of the vessel. These cable
coverings may also be grounded by means of glands specially intended for this purpose
317669/B
149
Содержание EM 122
Страница 1: ...EM 122 Multibeam echo sounder Installation Manual...
Страница 2: ......
Страница 13: ...EM 122 Figure 1 System diagram 317669 B 11...
Страница 26: ...EM 122 Figure 6 EM 122 Gondola example Cd021 107 24 317669 B...
Страница 27: ...Transducer arrays Figure 7 EM 122 blister and steel pipe arrangements example 317669 B 25...
Страница 42: ...EM 122 B B B Plastic TX protection window 40 317669 B...
Страница 46: ...EM 122 Figure 10 EM 122 Transceiver unit mounting 44 317669 B...
Страница 52: ...EM 122 Figure 13 Rear view 50 317669 B...
Страница 54: ...EM 122 Figure 15 Preamplifier Unit mounting 687 52 317669 B...
Страница 60: ...EM 122 Figure 18 Remote Control Junction Box outline dimensions 58 317669 B...
Страница 85: ...Cable layout and interconnections Figure 32 Transceiver Unit sub racks rear view 317669 B 83...
Страница 88: ...EM 122 Figure 34 Preamplifier underneath view 86 317669 B...
Страница 97: ...Cable layout and interconnections Figure 40 EM 122 Transceiver Unit s rear panel RX 317669 B 95...
Страница 126: ...EM 122 Figure 57 Cable layout 0 5 degree TX page 1 of 2 Cd021 106 Page 1 of 2 315396 Pro03 124 317669 B...
Страница 127: ...Drawing file Figure 58 Cable layout 0 5 degree TX page 2 of 2 Cd021 106 Page 2 of 2 315396 Pro03 317669 B 125...
Страница 128: ...EM 122 Ice window Figure 59 TX Ice window 126 317669 B...
Страница 129: ...Drawing file Figure 60 RX Ice window 317669 B 127...
Страница 131: ...Drawing file Preamplifier Unit Figure 62 RX Preamplifier Unit internal cabling 317669 B 129...
Страница 132: ...EM 122 Figure 63 RX Preamplifier Unit internal cabling 130 317669 B...
Страница 154: ...2013 Kongsberg Maritime...