Lighting Instructions

Warning: white smoke may appear around the radiant head during the first minutes of 

the initial firing.

Step 1

Ensure the control knob is off. Slowly open the gas cylinder valve.

Step 2

Push the control knob in and turn anti-clockwise to 'HIGH' whilst simultaneously 

pushing the ignitor button several times.

Step 3

Check for a flame at the burner. If the burner does not light immediately, turn the 

control knob to 'OFF' and try the instructions again from the start.  Allow 30 seconds 

between ignition attempts to allow the gas to dissipate. Several attempts may be 

necessary.

Failure to follow this procedure may result in flames rolling out beyond the emitter grid.

Step 4

With the burner alight, keep the control knob depressed for 15 seconds.

Step 5

For minimum heat, push the control knob in and turn it to 'LOW'.

Step 6

To turn the heater off, turn the control knob to 'OFF'.

Troubleshooting

Problem

Possible Causes

Main burner won't light

No gas

Low gas pressure

Blockage in hose or orifice

Manual valve not in the 'LOW' or 'HIGH' position

Note: if the heater cannot be adjusted to perform correctly, it should not be used until 

serviced or repaired.

Warning: improper installation, adjustment, alteration, service or maintenance can cause

injury or property damage. Any modifications or adjustments made to the product 

without prior authority from Kogan.com will void any warranty claims.

Read the installation, operation and maintenance instructions thoroughly before 

installing or servicing this equipment.

11

Содержание KDGASPATHTRA

Страница 1: ...and natural convection Please refer to examples overleaf in relation to these rules Any enclosure in which the appliance is used shall comply with the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover see Example 1 Within a partial enclosure that includes an overhead cover and no more than two walls see Examples 2 3 Within a par...

Страница 2: ...tion Children should be carefully supervised when they are in the area of the appliance NEVER hang anything including clothes or other flammable items on the appliance DO NOT operate this appliance unless it is fully assembled with heat reflectors in place DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS OPERATION Repairs should only be carried out by Kogan com technicians or ot...

Страница 3: ...ble even though flame proofed fire retardant treated or plastered Additional clearance may be required for glass painted surfaces or other materials which may be damaged by radiant or convection heat 4 Heaters must be places on a level and adequate footing and be readily accessible 5 The gas manifold supply pressure must be regulated at 2 75 kPa utilising an AGA approved regulator supplied with th...

Страница 4: ...d working condition When the cylinder is not in use be sure to cover it with a dust cap A leak test should be performed with soapy water whenever you connect a new cylinder NEVER use a match to test for leaks 11 The propane gas cylinder must be turned off whenever the heater is not in use When the heater is to be stored indoors the propane gas cylinder must be disconnected and stored in accordance...

Страница 5: ...Minimum Clearance from Combustible Surfaces combustible materials are considered to be wood compressed paper plant fibres plastic or mother materials that are capable of being ignited and burned 5 ...

Страница 6: ... wheel assembly to the base Line up the holes in the wheel bracket with the corresponding holes in the base Insert 2 x M6 bolts through the holes and finger tighten 2 x M6 nuts Be sure that the wheel assembly is parallel to the base and fully tighten the bolts Wheel Assembly 2pcs M6 Bolts 2pcs M6 Nuts Screw the sand tank back onto the base Remove the base cap and fill the base with fine sand 6 ...

Страница 7: ...n 3pcs M8 Bolts Step 4 Put the post on the post bracket Put the lower post on the bracket with 6 x M6x22 bolts and M6 nuts Then unscrew 4 x M5x10 screws from the lower post and attach the upper post to it 6pcs M6x22 Bolts 6pcs M6 Nuts 4pcs M5x10 Screws 7 Then fasten the lower post and upper post with 4 x M5x10 screws ...

Страница 8: ...rt 3 reflector studs Tight studs securely 3 Reflector Studs Step 7 Attach head assembly to post Unscrew 4 small screws then load the head assembly by inserting the hose into the post Attach the head assembly to the post then install the 4 small screws and tighten them securely 8 ...

Страница 9: ...e wing nuts however be sure to NOT over tighten them Step 9 Raise the cylinder housing and rest it on the post Connect the regulator to the hose using 2 spanners and conduct a leak check of the connection Step 10 Leak Check Connect the regulator to a full gas cylinder and test all gas connection using a soapy water solution If bubbles appear at a connection tighten that connection and repeat the l...

Страница 10: ...eak test all gas connections with soapy water Soap bubbles indicate gas leakage DO NOT use a match to test for gas leaks WARNING White smoke may appear around the radiant head during the first minute of the initial firing This is completely normal Abnormal Operation Any of the following are considered to be abnormal operations Yellow tips on the burner flames Fumes or strong odours Soot build up A...

Страница 11: ...t beyond the emitter grid Step 4 With the burner alight keep the control knob depressed for 15 seconds Step 5 For minimum heat push the control knob in and turn it to LOW Step 6 To turn the heater off turn the control knob to OFF Troubleshooting Problem Possible Causes Main burner won t light No gas Low gas pressure Blockage in hose or orifice Manual valve not in the LOW or HIGH position Note if t...

Отзывы: