26
Table 2
-
Scooter controller internal diagnostics
The diagnostic flash codes for your scooter are designed to help you perform basic
troubleshooting quickly and easily. A diagnostic flash code flashes from the
Status
Led
in the event of one of the conditions listed below.
Flash
code
Possible
Solution
1
The battery needs recharging.
The battery voltage has dropped below 23.3
volts in neutral. Recharge batteries.
2
Battery voltage too low.
The battery has dropped past 16.5 volts and is
not sufficient to allow safe driving. Check the
battery condition and the connections.
3
Battery voltage too high.
The battery has exceeded 32 volts. Check the
battery condition and the connections.
4
Current limit time out.
The motor current has reached too high a
value. Check the condition of the motor and
loom. Contact your Komfi-Rider dealer.
5
Park brake fault.
Check park brake conditions.
6
Speed control out of neutral.
Return speed pot to neutral and rest system.
Readjust the speed lever neutral if necessary.
Contact your Komfi-Rider dealer.
7
Speed control fault.
Check speed pot wiring for open or short
circuits. Check speed pot set-up. Contact your
Komfi-Rider dealer.
8
Motor fault.
Contact your Komfi-Rider dealer.
9
Internal (controller) fault.
Contact your Komfi-Rider dealer.