Foreword and general information
Method of disconnecting and connecting push-pull type coupler
PC800, 850-8E0
Type 3
00-25
1.
Disconnection
1) Hold the tightening portion and push body (9)
straight until sliding prevention ring (8)
contacts contact surface (b) of the hexagonal
portion at the male end. (Fig. 10)
2) While holding the condition of Step 1), push
cover (10) straight until it contacts contact
surface (b) of the hexagonal portion at the
male end. (Fig. 11)
3) While holding the condition of Steps 1) and
2), pull out whole body (9) to disconnect it.
(Fig. 12)
2.
Connection
q
Hold the tightening portion and push body (9)
straight until sliding prevention ring (8) con-
tacts contact surface (b) of the hexagonal
portion at the male end. (Fig. 13)
00-25