regulation of the boiler and view of the heating unit current
work mode. There is an ability to mount the panel for example
on a wall, metal base, or in any other place you choose.
Modern construction based on two processors allows
operation of the unit even without the panel. Any time you
can disconnect one of the panels (even the “0” panel) and the
driver will work anyway, ensuring the full control over work of
the boiler.
3.2 REMOTE PANELS SUPPLY
Each of remote control panels is directly powered from the
driver main housing. The device uses a standard 4-wire cable
with 0,5 cross-section which provides power supply (red and
blue wire) and data transmission (black and white wire).
Description of the panel socket and connection schematic are
placed in every panel on rear wall of the housing and in the
manual. Description of driver's socket connectors can be found
below. There is a possibility to power the panel from
independent power supply 12V connected to the wall socket
230V near the device and connect it with the driver central unit
by only a 2-wire cable transmitting information. Only two
central pins of the panel connector are used then (black and
white wire – data transmission).
When connecting more than one remote panel there is no
need to connect each panel with the driver! Just connect
for example 3 panels in series and only one of them
should be connected by a cable with the main driver.
6