3. Brown (L) and blue (N) wires should be connected to the
current terminal block.
4. Check whether the connections are correct and screw
the steering box.
Specific diagram of connecting the wires to circulation
pumps can be found in the pump manual.
Incorrect connection of the wires will cause damage
of the driver or devices connected. Installation can
be made only by authorized staff. Before
connecting the device, remember to remove the driver
power cord from the wall socket!!
3.1 CONNECTING REMOTE CONTROL
PANELS
Driver
TIGRA
enables connection of
FOUR
remote control
panels marked respectively 0,1,2,3. This number is displayed
when turning on the driver by the network button on the splash
screen. It is also visible on the tally of every panel. “0” panel is
the basic (main) panel, screwed to the main housing of the
driver or directly connected to the housing when the main
panel is mounted on the boiler and upper housing, for example,
behind the container or on rear/side wall of the boiler. On the
other hand, every additionally mounted panel in the apartment
will be of sequential number 1, 2 or 3. There is no possibility to
connect for example two panels of the same number. Driver
software automatically detects the connected panel and allows
it the control over the whole unit work. Every additional panel
looks the same as the main panel (0) and allows the full
5