Fig.
5.0
J1
connector to Kolver control units
B) Pins 1 to 4 send out the signals of OK/NOT-OK screws and CYLE/SEQUENCE END.
It features 2 relays to be used with up to 250VAC contacts: ideal to send for the signals to
external devices located in the medium-long distances or to light signals.
Pins are:
1) GND Output
2) OK Screw
3) NOK Screw
4) CYLE/SEQUENCE END
Fig 5.1 Signal connectors