9.3.6
Feedback
Press function key F12 (disable) before chan-
ging feedback parameters.
Feedback Type:
Select the feedback type used.
Leave all other fields unchanged.
If Software Enable is active, a warning appears.
The configuration change cannot be performed.
Click OK on the warnings, press F12 (SW disab-
le) and start the Feedback procedure again.
If everything was ok, the same procedure (para-
meter upload) that has been described for the
motor selection starts.
If you click "Yes", the parameters are saved in
the EEPROM and the amplifier makes a cold-
start (reset). This takes some seconds.
86
SERVOSTAR
®
640/670 Instructions Manual
Setup
12/2010
Kollmorgen
Содержание SERVOSTAR 640
Страница 12: ...3 2 1 EC Declaration of Conformity 12 SERVOSTAR 640 670 Instructions Manual Approvals 12 2010 Kollmorgen...
Страница 35: ...7 4 Dimensions SERVOSTAR 640 670 Instructions Manual 35 Kollmorgen 12 2010 Mechanical Installation...
Страница 44: ...8 6 Pin assignments 44 SERVOSTAR 640 670 Instructions Manual Electrical Installation 12 2010 Kollmorgen...
Страница 112: ...This page has been deliberately left blank 112 SERVOSTAR 640 670 Instructions Manual Expansion Cards 12 2010 Kollmorgen...