9.3.4
Basic Setup
On the start screen click "Basic Setup" button.
Regen Resistor:
Select "external" brake resistor
max.Regen Power:
Fill in the power of the connected brake resistor.
max. Mains Voltage:
Select the nominal mains AC voltage
Mains Phase Missing:
You can select either warning "n05" or error "F19" in case of phase loss.
The setting "F19" disables the output stage, "n05" is just a message.
Units: Acceleration, Velocity, Position
Select usable units for your application referring to the moved load.
Leave all other fields unchanged.
Click OK. On the start screen click "Motor" button.