S300 Safety Guide | 6 Appendix
6.3 Fault and Warning Messages
6.3.1 Error messages
Any errors that occur are shown in coded form by an error number in the LED display on the front panel. The
servo amplifier reaction depends on the fault and on the setting of parameter
. Faults can be reset by
hardware reset of the servo amplifier or depending on the fault (
) by ASCII command
.
Number Designation
Explanation
E/P
Status Messages
Status messages, no error
. . .
Status Message
Updating the startup configuration
-
Status Message
Programming mode
- S -
STO-Enable
STO-Enable input is 0V (with disabled drive only)
F01
Heat sink temperature Heat sink temperature too high limit is set by manufacturer to 80°
F02
Overvoltage
Overvoltage in DC bus link limit depends on the electrical supply voltage
F03
Following error
Message from the position controller
F04
Feedback
Cable break, short-circuit, short to ground
F05
Undervoltage
Undervoltage in DC bus link, limit is set by manufacturer to 100V
F06
Motor temperature
Motor temperature too high or temp. sensor defect
F07
Internal voltage supply Internal amplifier supply voltages are out of tolerance
F08
Overspeed
Motor over-revs, speed is too high
F09
EEPROM
Checksum error
F10
Signal Failure X5
Signal failure X5 (cable break or similar)
F11
Brake (motor)
Cable break, short-circuit, short to ground
F12
Motor phase
Motor phase missing (cable break or similar)
F13
Ambient temperature
Ambient temperature too high
F14
Output stage
Fault in the power output stage, also with wrong motor cable or insufficient
cable shielding
F15
I²t max.
I²t maximum value exceeded
F16
Mains BTB/RTO
2 or 3 phases missing in the mains supply feed
F17
A/D converter
Error in the analog-digital conversion, normally caused by extreme elec-
tromagnetic interferences.
F18
Brake Circuit
Brake circuit faulty or incorrect setting
F19
DC Bus Link
DC bus link breakdown
F20
Slot fault
Slot error, depends on the type of expansion card (see
F21
Handling error
Handling error on the expansion card
F22
Reserved
Reserved
F23
CAN-bus off
Severe CAN bus communication error
F24
Warning
Warning is displayed as fault
F25
Commutation error
Commutation error
F26
Limit switch
Hardware limit switch error on homing move
F27
STO
Operational error with STO, input for STO-Enable and ENABLE have been
set at the same time
F28
Fieldbus Error
see
F29
Slot/Fieldbus Error
see
F30
Emergency timeout
Timeout emergency stop
F31
Reserve
Reserve
F32
System Error
system software not responding correctly
148
Kollmorgen | wiki-kollmorgen.eu | December 2015
Содержание SERVOSTAR 300
Страница 30: ...S300 Safety Guide 1 Deutsch 30 Kollmorgen wiki kollmorgen eu December 2015...
Страница 58: ...S300 Safety Guide 2 English 58 Kollmorgen wiki kollmorgen eu December 2015...
Страница 86: ...S300 Safety Guide 3 Fran ais 86 Kollmorgen wiki kollmorgen eu December 2015...
Страница 114: ...S300 Safety Guide 4 Italiano 114 Kollmorgen wiki kollmorgen eu December 2015...
Страница 117: ...5 1 2 PDF 5 1 3 Symbol S300 Safety Guide 5 Kollmorgen wiki kollmorgen eu December 2015 117...
Страница 122: ...S300 Safety Guide 5 5 2 3 UN 230 B S300 122 Kollmorgen wiki kollmorgen eu December 2015...
Страница 126: ...S300 Safety Guide 5 5 3 2 SERVOSTAR 300 126 Kollmorgen wiki kollmorgen eu December 2015...
Страница 136: ...S300 Safety Guide 5 5 6 5 6 1 Wichtige Hinweise 900 5 60 AENA 1 30 L1 L2 136 Kollmorgen wiki kollmorgen eu December 2015...
Страница 137: ...5 6 2 Return 5 6 2 1 5 6 2 2 S300 Safety Guide 5 Kollmorgen wiki kollmorgen eu December 2015 137...
Страница 139: ...5 6 3 3 S300 Safety Guide 5 Kollmorgen wiki kollmorgen eu December 2015 139...
Страница 147: ...6 2 2 Connection overview SERVOSTAR 300 S300 Safety Guide 6 Appendix Kollmorgen wiki kollmorgen eu December 2015 147...
Страница 153: ...S300 Safety Guide Kollmorgen wiki kollmorgen eu December 2015 153...