AKI2G-CDB-MOD-12T-000 | SAFETY PRECAUTIONS

Terminal Block Connector

Wire Size AWG

TQ Lb.In.

X1/X100 Phoenix connectors

AWG 30–12

5–7

X1/X100 Anytek connectors

AWG 24–12

3.5

X1/X100 DECA connectors

AWG 24–12

7

These devices are Class 2 supplied programmable controllers (industrial PCs) for the use in
industrial control equipment and are intended to be (front) panel mounted (Type 12 and 4x for
indoor use only).

Caution:
The enclosure provides a degree of protection of at least IP20, but when installed in an
apparatus, it should meet IP65..
LE BOÎTIER OFFRE UN DEGRÉ DE PROTECTION D'AU MOINS IP20, MAIS
LORSQU'IL EST INSTALLÉ DANS UN APPAREIL, IL DOIT ÊTRE DE CLASSE IP65..

2.4

During Installation

The HMI panel is designed for stationary installation on a planar surface, where the following
conditions are fulfilled:

no high explosive risks

no strong magnetic fields

no direct sunlight

no large, sudden temperature changes

Install the HMI panel according to the accompanying installation instructions.

Ground the HMI panel according to the accompanying installation instructions.

Only qualified personnel may install the HMI panel.

Separate the high voltage, signal, and supply cables.

Make sure that the voltage and polarity of the power source is correct before connecting the HMI
panel to the power outlet.

Peripheral equipment must be appropriate for the application and location.

2.5

During Use

Keep the HMI panel clean.

Emergency stop and other safety functions may not be controlled from the HMI panel.

Do not use excessive force or sharp objects when operating the touch screen.

2.6

Service and Maintenance

Only qualified personnel should carry out repairs.

The agreed warranty applies.

Before carrying out any cleaning or maintenance operations, disconnect the equipment from
the electrical supply.

Clean the display and surrounding front cover with a soft cloth and mild detergent.

ky

Kollmorgen | April 2017

7

Содержание AKI2G-CDB-MOD-12T-000

Страница 1: ...rminal Installation Manual Edition A April2017 AKI2G CDB MOD 12T 00012 1 Touchscreen HMI Keep all manuals as a product component during the life span of the product Pass all manuals to future users ow...

Страница 2: ...ithout prior notice Printed in the United States of America This document is the intellectual property of Kollmorgen All rights reserved No part of this work may be reproduced in any form by photocopy...

Страница 3: ...3 2 2 Other Connections and Peripherals 11 4 Technical Data 5 Chemical Resistance 5 1 Metal Casing 14 5 2 Touch Screen and Overlay Material 15 5 2 1 Autoflex EBA 180L 15 5 2 2 Touch Screen Surface fo...

Страница 4: ...o understand and use Configuration is carried out on a PC using the Kollmorgen Visualization Builder configuration tool The project can then be transferred and stored in the operator panel itself Vari...

Страница 5: ...d the eye open flush with plenty of water and get medical attention The figures in this manual serve an illustrative purpose Because of the many variables associated with any particular installation t...

Страница 6: ...pproved expansion units are allowed to be connected to the port designated EXPANSION At the moment there are no such units evaluated or allowed SEULES LES UNIT S D EXTENSION CERTIFI ES UL ET cUL PEUVE...

Страница 7: ...fields no direct sunlight no large sudden temperature changes Install the HMI panel according to the accompanying installation instructions Ground the HMI panel according to the accompanying installat...

Страница 8: ...ng to local regulations The following components contain substances that might be hazardous to health and the environment lithium battery electrolytic capacitor and display 2 8 Appearance ofAir inTouc...

Страница 9: ...late thickness 12 8 mm The following drawings show the space requirements in millimeters when installing the operator panel The drawings are only illustrative and may be out of proportion 3 1 1 AKI2G...

Страница 10: ...e the cut out dimensions in the outline drawing For more information see sections Operator Panel Drawings and Technical Data 3 Install the HMI panel into the cutout 4 Secure the HMI panel in position...

Страница 11: ...net C Figure 3 2 The image is illustrative only and may differ slightly from the actual panel Connect cable A Connect cable B using an M5 screw and a grounding conductor as short as possible that is s...

Страница 12: ...wder coated aluminum Frame material Powder coated aluminum Weight 2 6 kg CPU i MX6DualLite Dual Cortex A9 1 0 GHz 512 kB L2 cache Serial port for COM1 RS232 COM2 RS422 RS485 and COM3 RS485 9 pin D sub...

Страница 13: ...H 261 1 x 163 2 mm Pixel errors Class I ISO 9241 307 Backlight brightness 400 cd m2 Backlight lifetime 50 000 hours Operating temperature 10 C to 60 C Storage temperature 20 C to 70 C Relative humidi...

Страница 14: ...nce to the following chemicals at room temperature Butanol Nitric acid 3 Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric acid 43 Sodium hypochlorite 10 Turpentine Note If exposure to a...

Страница 15: ...c soda 40 1 Methanol Trichloroacetic acid 50 Cutting oil Nitric acid 10 White Spirit Cyclohexanol Paraffin oil Windex 1 Diacetone alcohol Persil powder in solution 1 1 Extremely faint glossing of the...

Страница 16: ...2 3 TouchScreenProtector For harsh environments and exposure to outdoor conditions it is recommended to use a protective film to guard the touch screen from damage This optional part can be ordered f...

Страница 17: ...nnectors Figure 6 1 AKI2G CDB MOD 12T 000 Pos Connector Description 1 Power supply 24 V DC 18 32 V DC 2 USB USB Host 2 0 max output current 500 mA 3 LAN A 10 100 Base T shielded RJ45 4 LAN B 10 100 Ba...

Страница 18: ...TxD 4 RS422 Rx RS485 Tx Rx 5 GND GND 6 RS422 Tx RS485 Tx Rx 7 RS232 RTS 8 RS232 CTS 9 RS422 Rx RS485 Tx Rx Note In order to utilize two communication ports the Y split cable CAB109 must be used In ord...

Страница 19: ...L DRAWINGS 6 3 Digital Outputs Ratings Maximum supply voltage 32 0V DC 22Vrms AC Maximum load current 0 5A DC 0 5Arms AC Isolation Channel to Channel 1000V DC 550Vrms AC Channel to System 1000V DC 550...

Страница 20: ...AKI2G CDB MOD 12T 000 OPERATOR PANEL DRAWINGS 6 4 AKI2G CDB MOD 12T 000Outline Figure 6 2 AKI2G CDB MOD 12T 000 ky Kollmorgen April 2017 20...

Страница 21: ...ectly according to local electrical codes between the chassis of the HMI panel and the closest grounding point on the door see 3 in drawing above 3 Connect a strong but short grounding braid between t...

Страница 22: ...ther Ethernet unit has its shield directly grounded or grounded via a capacitor Note In many cases connecting the shielded Ethernet cabling to the chassis at bothends is inappropriate Hum or grounding...

Страница 23: ...ternative is to connect the other end of the shield to the ground via a 0 1 F 250 V plastic capacitor Both ends are then connected to the ground in terms of HF but only connected to the ground at one...

Страница 24: ...acitor is cut in half with an 8 10 C increase in temperature A 15 20 C temperature increase results in a quarter of the lifespan etc Rittal has a good program for estimating the anticipated average te...

Страница 25: ...re for example SELV according to EN 60950 protection against electric shock and UL 950 Note Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with...

Страница 26: ...n for example a USB memory stick keyboard or similar device is plugged in If a number of units are connected that have a 0 V and a ground connection and these are connected to various grounding points...

Страница 27: ...he shield must be grounded at one end The other end is usually grounded but with longer distances or when there is a difference in the ground potential the shield should be connected to the ground via...

Страница 28: ...20 seconds 3 Enter a PIN code if the service menu is password protected 4 The touch calibration screen displays the following message Tap anywhere on screen or touch calibrate will start in 10 second...

Страница 29: ...the X32 port and any combination can be active simultaneously When incorporating an AKI HMI panel into a KAS IDE Project variables that are planned to be used inside the KVB software are designated by...

Страница 30: ...red into KVB when it is opened from inside the KAS IDE KAS IDE KVB Additionally the PxMM s IP address is also transferred into the KVB project when it is opened from within the KAS IDE To open KVB fro...

Страница 31: ...Template Project some of the template projects will contain a KVB Project Double clicking on it will also launch KVB In this scenario tags and the target IP address are imported into KVB but the AKI P...

Страница 32: ...ge base for answers get downloads and suggest improvements North America Europe KOLLMORGEN KOLLMORGEN Europe GmbH 203A West Rock Road Pempelfurtstra e 1 Radford VA 24141 USA 40880 Ratingen Germany Web...

Отзывы: