AKD2G-S Installation Manual, Safety 1 | 6 Technical description and data
Auxiliary supply voltage 24VDC
From an external, safety approved 24 V ±10% power supply (PELV).
Parameter setting
Setup software WorkBench for setup by using TCP/IP.
Download control parameter packages by using CoE
Full digital control
Digital current loop (update 1.28 µs / command 62.5 µs)
Digital velocity loop (update period 62.5 µs)
Digital position loop (update period 250 µs)
Inputs/Outputs (X21/X22/X23)
2 programmable analog input (
2 programmable analog output (
12 programmable digital inputs (
8 programmable digital outputs (
6 programmable digital input/outputs (
4 safe STO inputs (dual channel STO per axis) (
Connector Options
IO
: X22 connector with additional digital inputs and outputs.
F3
: X23 connector for conventional motor feedbacks (Resolver, SFD, Tamagawa Smart
Abs, Comcoder, 1Vp-p Sin-Cos encoders, incremental encoders, EnDAT 2.1/2.2 and
HIPERFACE).
DX
: all possible connectors for extended I/O and feedback connections.
Customization
0000: uncoated PCBs, standard
0xxx: uncoated PCBs, customized coding
A000: coated PCBs, standard
Axxx: coated PCBs, customized coding
Connectivity
Feedback inputs (
Encoder emulation output (
Digital Inputs/Outputs (
Service Interface (
Modbus Interface (
CANopen (
EtherNet Fieldbus interface (
Accessories
SFA
(Smart Feedback Adapter) (
Hybrid motor cables, motor power cables, motor feedback cables.
External regen resistors.
For accessories refer to your regional
Accessories Manual
.
30
Kollmorgen | kdn.kollmorgen.com | July 2020