Attribute 0x04: Position Units
Description
This ratio value is the number of 32-bit actual position feedback counts equal to one position
unit.
Access Rule
Get / Set
Data Type
U32
Range
0 to 231
Default
65536 (16 bits/revolution)
Non-Volatile
Yes
See Also
N/A
Attribute 0x05: Profile Units
Description This ratio value is the number of 32-bit actual position feedback counts per second (velocity) or
second squared (acceleration) equal to one velocity or acceleration unit.
Access
Rule
Get / Set
Data Type
U32
Range
0 to 231
Default
65536 (16 bits/revolution)
Non-Volat-
ile
Yes
See Also
N/A
Attribute 0x06: Target Position
Description This attribute specifies the target position in counts. Set Start Trajectory=1 (attribute 11) or the
Polled I/O Start Trajectory/Load Data bit to initiate the positioning move.
Access
Rule
Get / Set
Data Type
Double Integer
Range
-231 to 231
Default
0
Non-Volat-
ile
No
See Also
N/A
Attribute 0x07: Target Velocity
Description This attribute specifies the target velocity in counts per second. Use target velocity for pos-
ition opmode and jog velocity (attribute 22) for velocity opmode. Units are determined by the
amplifier setup (VUNIT, Position controller attributes 40-41)
Access
Rule
Get / Set
Data Type
Double Integer
Range
Set to a positive number
Default
According to setup
Ethernet/IP Communications | 7 Drive Objects