Ethernet/IP Communications | 9 EIP Parameters
9.3 EIP.POSUNIT
General Information
Type
R/W
Description Unit scaling for Position values over EtherNet/IP.
Units
N/A
Range
0 to 4,294,967,295
Default
Value
65536
Data Type
Integer
Start Ver-
sion
M_01-05-00-000
Variants Supported
Variant
Supported
AKD Base
No
AKD with Position Indexer
No
AKD EtherCAT
No
AKD CANopen
No
AKD BASIC
No
AKD SynqNet
No
AKD EtherNet/IP
Yes
AKD Profinet
No
AKD sercos® III
No
AKD-N
No
AKD-C
No
Fieldbus Information
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus
1590
No
32-bits
No
M_01-06-03-000
Description
Position values are scaled according to the Ethernet/IP Position Controller Device standard. One “Position
Units” scaling value is defined, which gives the number of actual position feedback counts (at 32 bits per
revolution) equal to one position unit.
From Workbench, this scaling parameter is visible in the Ethernet/IP screen or as EIP.POSUNIT in the ter-
minal. From Ethernet/IP, this value can be accessed at attribute 0x04 Position Units of the Position Con-
troller object.
The default value is 2^16 = 65536, which provides 2^32 / 2^16 = 2^16 counts per revolution. A value of 1
would provide 2^32 / 1 = 2^32 counts per revolution.