background image

Catalogue

1.Safety…………………………………………..1

2.Specifications…………………………………4

3.Component  Identification…………………...5

4.Preparation……………………………….…..9

5.Starting……………………………………….12

6.Operation…………………………………....13

7.Engine Shut down…........………………….14

8.Maintenance…………………………………15

9.Common Faults and troubleshooting…....23

10.Schematic

 

Diagram………………………26

Содержание VOLT VK4X1E

Страница 1: ...Owners Manual MODEL VK4X1E OPERATOR S MANUAL 4 In 1...

Страница 2: ...re operating the machine Operating the machine in the best conditions will increase the lifetime of the unit If you have any suggestions for the manual please contact your local dealer We as a company...

Страница 3: ...e 1 Safety 1 2 Specifications 4 3 Component Identification 5 4 Preparation 9 5 Starting 12 6 Operation 13 7 Engine Shut down 14 8 Maintenance 15 9 Common Faults and troubleshooting 23 10 Schematic Dia...

Страница 4: ...rking molten metal splashing Looking at welding arc without eye protection can inflict great pain and even temporary blindness Therefore this products owner operator should ensure the welding machine...

Страница 5: ...anywhere near the machine even if someone else is operating The magnetic field produced by the welding machine could have adverse effects on a pacemaker 1 7 Welding splatter can cause fire and explosi...

Страница 6: ...rks etc Make sure to wipe all leaked fuel on the unit before starting 1 12 Take care when attaching your welding leads Ensure a solid connection at the lead terminals at all times Inspect your welding...

Страница 7: ...Engine Working voltage V Lamp power W Solenoid valve Lifting gear pressure MPa Lift height mm AC120V 240V 5 LED 4 100W 2pcs DC12V 5W 0 8 0 1 1800 4500 50A 200A Welding AC120 240V 60Hz 2 Specification...

Страница 8: ...d could present the potential for equipment failure and personal injury Component Identification 1 Main Switch 2 Air compressor switch 3 Display meter 4 Oil alarm 5 key switch 6 Welding adjustor 7 Soc...

Страница 9: ...hoke Lever 6 Air Filter Assembly 7 Handle 8 Water Drain Valve 9 Muffler Assembly 10 Frame 1 Air Compressor Oil Drain Plug 2 Oil Sight Glass 3 AVR Cover Plate 4 Control Panel Case 5 Exhaust Port 6 Oil...

Страница 10: ...ain Plug 2 Oil Fill Dipstick 3 Air Pressure Relay 4 A C Switch 5 Safety Valve 1 Pressure Gauge 2 Air Pressure Regulator 3 Air Outlet Connectors 4 Pressure Gauge 5 Air Tank 6 Air Hose 7 Air Valve 8 Whe...

Страница 11: ...1 Lighting fixing device 2 Lighting shift device 3 Lift and drop arod assy 4 Lamps assy 1 Air outlet 2 Lighting lock device 3 Lighting fixing device...

Страница 12: ...a clean dry well ventilated place 4 4 Please check to ensure all components of machine are securely fastened If fastener or connectors are loose they must be repaired before running the machine 4 5 Ma...

Страница 13: ...erent average temperatures 4 5 3 If the oil level is below the minimum level add oil to its proper level We recommend the oil is in the middle of minimum and maximum levels Always check the API SERVIC...

Страница 14: ...1 Open the clip to loosen the filter cover 4 8 2 Move the clip and filter cover in order to remove the air filter Do not damage the cover 4 8 3 Remove the Filter 4 8 4 Check the filter If the filter i...

Страница 15: ...ing the carb 5 2 1 Electric start on the unit Operate by turning the starting key on the control panel Turn the key in a clockwise direction to start location until the unit starts Return the key to o...

Страница 16: ...Remote control start Make sure the key is in the on location Then press the button on the remote control that reads on If failed retry after 30 seconds 6 Operation 6 1 Ambient temp welding 14 F 104 F...

Страница 17: ...compressor at the same time or generator and welder at the same time for best performance 6 6 Welding rods and welding leads chart For your reference below these are the rods and cables we see the bes...

Страница 18: ...Maintenance It is very important to get the best out of the product that you keep up on all maintenance Regular oil and fluid changes will also ensure you are decreasing the amount of pollution being...

Страница 19: ...ssar please replace Change oil when warm the unit remove the oil to make sure that the drain the oil completely 8 1 Changing the oil Make sure you warm up the unit for a short period of time to ensure...

Страница 20: ...e warm soapy water when cleaning the air filter Make sure you dry the filter before installing 8 3 Spark Plug Maintenance In order to keep your 4 in 1 running at peak performance the spark plug must b...

Страница 21: ...nician for any information 8 3 5 Install the spark plug cap 8 4 Battery maintenance When running the machine charging system will charge battery But it is for periodically use battery should be charge...

Страница 22: ...the plug is broken please replace the spark plug 8 3 3 Use the plug gauge to measure the gap between the electric poles If necessary you can slightly bend the electric pole to adjust the gap The gap...

Страница 23: ...If you will not be running the unit for 30 days or longer we strongly urge you turn the fuel petcock off and run the unit until the remaining fuel is burned off 8 5 2 Metamorphic fuel will cause diff...

Страница 24: ...all fuel into a container re tighten the discharge bolt 8 6 4 Put the container under the sedimentation glass and use a funnel to protect against over spill 8 6 5 Dismantle sedimentation glass and tur...

Страница 25: ...mpressor oil in the summer Open the drain oil bolt which is located under the main fuel tank After the oil has fully drained tighten the bolt and then add oil 8 7 3 Inspect the oil level before use Do...

Страница 26: ...AVR control panel broken 5 Short circuit open circuit or grounded wire 6 Circuit breaker not open 1 After confirm stop machine and replace 2 Check and repair 3 Clean slip ring or replace brush or conn...

Страница 27: ...kage or damage 5 compressor can not stop automatically 1 reduce working pressure 2 reference this manual and use correct compressor oil 3 Shift to good ventilation place 4 repair valve block or replac...

Страница 28: ...2 short circuit 3 the air pressure was not enough 4 the drop and rise switch on the contrl panel damaged 5 air leakage 1 change solenoid valve 2 check the wires and reconnect 3 Adding the air pressur...

Страница 29: ...10 Schematic diagram 26...

Страница 30: ...Notes Volt Email INFO VOLT EQUIPMENT COM TEL 1 888 207 VOLT MAILING 128 MILPORT CIRCLE SUITE 101 GREENVILLE SC 29607...

Страница 31: ......

Страница 32: ......

Отзывы: