background image

alternator

 

smoking

  

1

Rotor

 

and

 

s

tat

or

 ru

b

 

2

 

overload 

3

 

winding

 

short

 

circuit

 

or

 

grounded

 

4

 

MDS

 

or

 

rectifier

 

diode

 sho

rt

 

circuit

 

or

 gr

ounded

 

1

.

Replace

 

or

 

repair

 

2

.

Remove

 

some

 

load

 

3

.

Replace

 

alternator

 

winding

 

4. Replace

 

MDS

 

module

 

or

 

rectifier

 

diode

 

air

 

compressor

 

do

 

not

 

w

ork 

1

 

alternator

 

no

 

output

 

2

 

compressor

 

damage

 

3

 

bottom

 

manual

 

control

 

switch

 

is

 

close

 

4

 

pressure

 

relay

 bro

ken

 

5

 

special

 

circuit

 

breaker

 

on

 

control

 

panel

 

work

 

6

 

thermal

 

protector

 

at

 

alternator

 

bottom

 

work

 

1

inspect

 

alternator

 

and

 

AVR

 

2

contact

 

supplier

 

to

 

repair

 

or

 

replace

 

3

open

 

manual

 c

ontrol

 

switch

4

replace

 

pressure

 

relay

 

5

i

ns

pect

 

and

 

recover

 

6

recover

 

or

 re

place

 

compressor

 

part

 

overheat

 

temperature

1

Working

 

pressure

 

high

2

Not

 

use

 co

rrect

 lu

bricating

 

oil

 

3

Ambient

 hi

gh

 tem

perature

 or p

oor

 

ventilation

 

4

compressor

 

valve

 

block

 

air

 

leakage

 

or

 

damage

 

5

compressor

 

can

 

not

 

stop

automatically

 

1

reduce

 w

o

r

king

 

pressure

 

2

reference

 

this

 

manual

 

and

 use 

correct

 

compressor

 

oil

 

3

Shift

 

to

 

good

 

ventilation

 

place

 

4

repair

 v

al

v

e

 

block

 

or

 

replace

compressor

 

5

inspect

 

or

 

replace

 safety valv

e

 

o

pressure

 re

lay

.

compressor

 

heavy

 

1

Discharge

 

pressure

 

high

2

compressor

 

positioning

 

bolt

 

loose

 

1

reduce

 

discharge

 

pressure

 

2

r

ep

osition

vibrate

 

or

 

installation

 

out

 

of

 

level

 

compressor

 

pressure

 

value

 

can

 

Can not get 

to go up or 

down 

 

rated

 

pressure

 

1

Gas

 

circuit

 

not

 

sealed

 

well

 

2

vent

 

valve

 

air

 

leakage

 

3

pressure

 

gage

 

broken

 

4

safety

 v

alve

 

air

 

leakage

 

5

purge

 v

al

v

e

 

air

 

leakage

 

6

compressor

 

stator

 

or

 

ro

tor sho

rt

circuit

7

compressor

 

valve

 

block

 

air

 

leakage

 

or

 

damage

 

1

Inspect

 

or

 

re

-

seal

 

2

replace

3

replace

4

replace

5

replace

6

replace

7

repair

 v

al

v

e

 

block

 

or

 

replace

compressor

 

gasholder

 

pressure

 

high

 or 

safety

 v

alve

 

alerting

 

1

safety

 

valve

 

work

 

pr

es

sure

 

high

 

2

s

af

ety

 

valve

 

damage

 

3

pressure

 

relay

 broken

1

readjust

 pr

essure

 

working

 v

alue

2

replace

3

replace

24

Содержание VOLT VK4X1E

Страница 1: ...Owners Manual MODEL VK4X1E OPERATOR S MANUAL 4 In 1...

Страница 2: ...re operating the machine Operating the machine in the best conditions will increase the lifetime of the unit If you have any suggestions for the manual please contact your local dealer We as a company...

Страница 3: ...e 1 Safety 1 2 Specifications 4 3 Component Identification 5 4 Preparation 9 5 Starting 12 6 Operation 13 7 Engine Shut down 14 8 Maintenance 15 9 Common Faults and troubleshooting 23 10 Schematic Dia...

Страница 4: ...rking molten metal splashing Looking at welding arc without eye protection can inflict great pain and even temporary blindness Therefore this products owner operator should ensure the welding machine...

Страница 5: ...anywhere near the machine even if someone else is operating The magnetic field produced by the welding machine could have adverse effects on a pacemaker 1 7 Welding splatter can cause fire and explosi...

Страница 6: ...rks etc Make sure to wipe all leaked fuel on the unit before starting 1 12 Take care when attaching your welding leads Ensure a solid connection at the lead terminals at all times Inspect your welding...

Страница 7: ...Engine Working voltage V Lamp power W Solenoid valve Lifting gear pressure MPa Lift height mm AC120V 240V 5 LED 4 100W 2pcs DC12V 5W 0 8 0 1 1800 4500 50A 200A Welding AC120 240V 60Hz 2 Specification...

Страница 8: ...d could present the potential for equipment failure and personal injury Component Identification 1 Main Switch 2 Air compressor switch 3 Display meter 4 Oil alarm 5 key switch 6 Welding adjustor 7 Soc...

Страница 9: ...hoke Lever 6 Air Filter Assembly 7 Handle 8 Water Drain Valve 9 Muffler Assembly 10 Frame 1 Air Compressor Oil Drain Plug 2 Oil Sight Glass 3 AVR Cover Plate 4 Control Panel Case 5 Exhaust Port 6 Oil...

Страница 10: ...ain Plug 2 Oil Fill Dipstick 3 Air Pressure Relay 4 A C Switch 5 Safety Valve 1 Pressure Gauge 2 Air Pressure Regulator 3 Air Outlet Connectors 4 Pressure Gauge 5 Air Tank 6 Air Hose 7 Air Valve 8 Whe...

Страница 11: ...1 Lighting fixing device 2 Lighting shift device 3 Lift and drop arod assy 4 Lamps assy 1 Air outlet 2 Lighting lock device 3 Lighting fixing device...

Страница 12: ...a clean dry well ventilated place 4 4 Please check to ensure all components of machine are securely fastened If fastener or connectors are loose they must be repaired before running the machine 4 5 Ma...

Страница 13: ...erent average temperatures 4 5 3 If the oil level is below the minimum level add oil to its proper level We recommend the oil is in the middle of minimum and maximum levels Always check the API SERVIC...

Страница 14: ...1 Open the clip to loosen the filter cover 4 8 2 Move the clip and filter cover in order to remove the air filter Do not damage the cover 4 8 3 Remove the Filter 4 8 4 Check the filter If the filter i...

Страница 15: ...ing the carb 5 2 1 Electric start on the unit Operate by turning the starting key on the control panel Turn the key in a clockwise direction to start location until the unit starts Return the key to o...

Страница 16: ...Remote control start Make sure the key is in the on location Then press the button on the remote control that reads on If failed retry after 30 seconds 6 Operation 6 1 Ambient temp welding 14 F 104 F...

Страница 17: ...compressor at the same time or generator and welder at the same time for best performance 6 6 Welding rods and welding leads chart For your reference below these are the rods and cables we see the bes...

Страница 18: ...Maintenance It is very important to get the best out of the product that you keep up on all maintenance Regular oil and fluid changes will also ensure you are decreasing the amount of pollution being...

Страница 19: ...ssar please replace Change oil when warm the unit remove the oil to make sure that the drain the oil completely 8 1 Changing the oil Make sure you warm up the unit for a short period of time to ensure...

Страница 20: ...e warm soapy water when cleaning the air filter Make sure you dry the filter before installing 8 3 Spark Plug Maintenance In order to keep your 4 in 1 running at peak performance the spark plug must b...

Страница 21: ...nician for any information 8 3 5 Install the spark plug cap 8 4 Battery maintenance When running the machine charging system will charge battery But it is for periodically use battery should be charge...

Страница 22: ...the plug is broken please replace the spark plug 8 3 3 Use the plug gauge to measure the gap between the electric poles If necessary you can slightly bend the electric pole to adjust the gap The gap...

Страница 23: ...If you will not be running the unit for 30 days or longer we strongly urge you turn the fuel petcock off and run the unit until the remaining fuel is burned off 8 5 2 Metamorphic fuel will cause diff...

Страница 24: ...all fuel into a container re tighten the discharge bolt 8 6 4 Put the container under the sedimentation glass and use a funnel to protect against over spill 8 6 5 Dismantle sedimentation glass and tur...

Страница 25: ...mpressor oil in the summer Open the drain oil bolt which is located under the main fuel tank After the oil has fully drained tighten the bolt and then add oil 8 7 3 Inspect the oil level before use Do...

Страница 26: ...AVR control panel broken 5 Short circuit open circuit or grounded wire 6 Circuit breaker not open 1 After confirm stop machine and replace 2 Check and repair 3 Clean slip ring or replace brush or conn...

Страница 27: ...kage or damage 5 compressor can not stop automatically 1 reduce working pressure 2 reference this manual and use correct compressor oil 3 Shift to good ventilation place 4 repair valve block or replac...

Страница 28: ...2 short circuit 3 the air pressure was not enough 4 the drop and rise switch on the contrl panel damaged 5 air leakage 1 change solenoid valve 2 check the wires and reconnect 3 Adding the air pressur...

Страница 29: ...10 Schematic diagram 26...

Страница 30: ...Notes Volt Email INFO VOLT EQUIPMENT COM TEL 1 888 207 VOLT MAILING 128 MILPORT CIRCLE SUITE 101 GREENVILLE SC 29607...

Страница 31: ......

Страница 32: ......

Отзывы: