C. Installation of P-trap
C.
1. Insert drainage pipe with inner diameter
110mm into
drain elbow and weld.
1.
110mm
-10-
C. Method four: Cut apart the cable of the air hose. Pull
it out from the front of the tank and meanwhile
reserve the access panel. Fix the four plates with
screws and then fix the support board.
No direct contact between the faceplate and the
tank.
7~20mm thickness recommended for the wall of
the pinch plate.
Note:
Recommended installation hole size of
X
mm to remote plate installation.
201
136
C.
7~20mm
X
mm
201
136
Pinch plate installation
Screw
Air hose
Air hose
Pinch plate
Pinch plate
Pinch plate
Finished wall
Finished wall
Faceplate
Supporting Board
Supporting
Board
Method four:
Press from front
7~20mm recommended
7~20mm
+2
0
+2
0
+2
0
+2
0
+2
0
+2
0
+2
0
+2
0
2) K-23055T-PNE access panel installation and installation
hole size
2) K-23055T-PNE
There is only remote installation with K-23055T-PNE,
During remote installation, fix the cover onto the tank
and pull the air hose to the panel. Reserve access panel
at front to ensure removal and installation of cover.
Recommended installation hole size of
146
.
X 41
mm
146
X 41
mm
41
146
+2
0
+2
0
Pinch Plate
Wall Thickness 7~40mm
7~40mm
Adjust length of
pinch plate in
accordance with
wall thickness
At least 80mm gap reserved
80mm
Water Tank Bracket
Drainage Pipe
80
3mm gap reserved
80
3mm
80
3mm gap reserved
80
3mm
1402749-T01-A