background image

-1-

VEIL

INSTALLATION INSTRUCTIONS

WALL-HUNG TOILET

K-20534T-S/K-29917T-S/K-29918T-S/K-29919T-S

K-20535T-S/K-25092T-S/K-25093T-S/K-31010T-ZY/K-25094T-GS

K-21378T-CPS/K-21378T-BNS/K-21379T-CPS/K-21379T-BNS/K-25447T-NS

BEFORE YOU BEGIN

·

·

·

Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
These instructions contain important care, cleaning, and
warranty information-

please leave instructions for the

consumer.

ORDERING INFORMATION

VEIL WH Toilet (HT100 TL IWT)...........................K-20534T-S

Includes Bowl ........................................................K-5723T
Includes HYDRO-TOWER 100

Touchless In-Wall Tank ..................K-6281T-VLS

Includes Quiet-Close Toilet Seat ..........................K-4141T

VEIL WH Toliet (HT200 PNE IWT) .......................K-29917T-S

Includes Bowl ........................................................K-5723T
Includes HYDRO-TOWER 200 PNE

In-Wall Tank .................................K-20007T-VLS

Includes Quiet-Close Toilet Seat ..........................K-4141T

VEIL WH Toliet (HT300 PNE IWT) .......................K-29918T-S

Includes Bowl ........................................................K-5723T
Includes HYDRO-TOWER 300 PNE

In-Wall Tank ................................K-20010T-VLS

Includes Quiet-Close Toilet Seat ..........................K-4141T

VEIL WH Toliet (HT300 MEC IWT).......................K-29919T-S

Includes Bowl ........................................................K-5723T
Includes HYDRO-TOWER 300

In-Wall Tank W/ Frame...................K-4179T-VLS

Includes Quiet-Close Toilet Seat ..........................K-4141T

VEIL WH Toilet (HT100 MEC IWT).......................K-20535T-S

Includes Bowl ........................................................K-5723T
Includes HYDRO-TOWER 100

In-Wall Tank W/ Frame...................K-6284T-VLS

Includes Quiet-Close Toilet Seat ..........................K-4141T

·

·

·

-

(

100

).........K-20534T-S

..................................................................K-5723T

100

..........................K-6281T-VLS

(

) .................K-4141T

(

200

)................K-29917T-S

..................................................................K-5723T

200

...............................K-20007T-VLS

(

) .................K-4141T

(

300

)................K-29918T-S

..................................................................K-5723T

300

...............................K-20010T-VLS

(

) .................K-4141T

(

300

)................K-29919T-S

..................................................................K-5723T

300

........................................K-4179T-VLS

(

) .................K-4141T

(

100

)...............K-20535T-S

..................................................................K-5723T

100

........................................K-6284T-VLS

(

) .................K-4141T

©

©

Copyright Kohler China Investment Co., Ltd. 2019

2019

No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC

POST CODE 528137

2

528137

8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA

256410

8

256410

NO.1 KOHLER STREET, ECONOMIC DEVELOPMENT ZONE OF FAKU COUNTY, SHENYANG LIAONING PROVINCE, PRC

110400

1

110400

:

POST CODE:

POST CODE:

1247360-T01-G

Содержание VEIL W/SC ST HT200 M

Страница 1: ...K 4141T VEIL WH Toliet HT200 PNE IWT K 29917T S Includes Bowl K 5723T Includes HYDRO TOWER 200 PNE In Wall Tank K 20007T VLS Includes Quiet Close Toilet Seat K 4141T VEIL WH Toliet HT300 PNE IWT K 29...

Страница 2: ...5 5 0 K 25447T NS Includes Bowl K 5723T Includes HT 201 PNE IWT W F 3 5 5 0L VEIL WH K 25440T VL 100 K 25092T S K 5723T 100 K 21298T VLS K 4141T 100 K 25093T S K 5723T 100 K 22524T VLS K 4141T 200 3 5...

Страница 3: ...easure Tubing cutter Level Hacksaw Putty knife Screwdriver Straight pipe coupling Connection packing 254mm ROUGHING IN Unit mm Fig 1 1 Reference Value Kohler reserves the right to change marked dimens...

Страница 4: ...ank for SKU of faceplate Note Recommended rank dimension Fig 2 b 1 Rank should support weight 400kg 1 2 Install Manual Valve Or Sensor Refer to installation instructions of manual valve or sensor for...

Страница 5: ...smoothly 3 Fig 4 4 Inlet Outlet 4 Install The New Bowl Apply a little silicone sealant along the edge to fill the gap between bowl and wall See Fig 5a 4 5a Fig 5a 5a Fig 5b 5b Place the new bowl on th...

Страница 6: ...ctions 5 INSTALL THE SIDE PANELS The left panel L and right panel R are not interchangeable and they shall be respectively fixed onto the left side and right side of the bowl as shown in Fig 6 Align t...

Страница 7: ...ttings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing ch...

Страница 8: ...pares not provided by Kohler This product complies with GB26730 2011 GB26730 2011 Ordering Information HT201 PNE IWT W F 2 6 4 0 K 25439T PNE NA HT201 PNE IWT W F 3 0 4 5 K 25440T PNE NA HT201 PNE IWT...

Страница 9: ...4151T Design And Installation Concept Of In wall Tank Installation of in wall tank is much easier and nice looking comparative to that of traditional tank Meanwhile the space layout will be more reaso...

Страница 10: ...erature 1 45 C C C C C C C C 1 55 1 45 Full flushing volume Half flushing volume 6 L 3 L 6 L 3 L 0 0 0 0 K 25440T PNE NA K 25440T PM NA K 25440T RU NA K 25440T ML NA K 25443T PNE NA K 25443T PM NA K 2...

Страница 11: ...PM K 25440T RU K 25440T ML K 25441T PNE Installed with K 20341T PNE K 20341T PNE Method one Press from top Method two Remote plate installation Method three Remote installation of mask Method four Pr...

Страница 12: ...ggested faceplate installation area R1000mm 59 1 Finished wall Finished Floor Height to floor is decided by bowl K 23055T PNE 155 5 1 51 1 K 24149T K 24151T 225 1 160 1 20 72 Suggested 80 3 Kohler res...

Страница 13: ...ove paper board support block and plug above bracket assembly 1 2 Insert the frame screw and screw cap in the holes of fixing frame lock the frame screw with nut then tighten the frame screws on the f...

Страница 14: ...the tank to remain level 4 A B Hexagonal Screw Loosen Tighten Level Medinm Allen Key Adjustable Bracket Spanner Screw Screw Screw Expanding Bolt Cap Expanding Bolt Cap Washer Washer B Floor Discharge...

Страница 15: ...75890T PNE K 24149T K 24151T Access Panel Installation Methods There are four ways to install access panel Method one Press from top Method two Remote plate installation fix four plates with screws Me...

Страница 16: ...mmended for the wall of the pinch plate and 80 3mm gap is reserved Method three During remote installation of mask 4 holes with diameter of 10mm and depth of 12mm are needed to be reserved at the loca...

Страница 17: ...plate Pinch plate Finished wall Finished wall Faceplate Supporting Board Supporting Board Method four Press from front 7 20mm recommended 7 20mm 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 K 23055T PNE access...

Страница 18: ...rve access panel at front or top of the tank Note D Installation of Toilet D 1 Install the inlet pipe to the lavatory as shown and mark on the pipes at the back side of the tank with a ruler and a pen...

Страница 19: ...needed it should be adjusted with screwdriver or by hand Then apply lubricant to drainage pipe and limber pipe to ensure a smooth installation 4 48mm 58mm 48mm 58mm Long Screw Lubricant 5 Install the...

Страница 20: ...NE K 24149T K 24151T 2 Tighten four screws to LOCK mark after installing supporting board as shown 2 LOCK 3 Install the big flush air hose and small flush air hose to the cover Cut the excessive parts...

Страница 21: ...ceplate fixed frame installation direction 3 2 1 3 2 1 Half Flush Button Air Hose Faceplate Full Flush Button 2 2 Connect air hose to faceplate from water tank 3 3 Insert faceplate into faceplate fixe...

Страница 22: ...d then locate the installation hole of fixing bracket Mark on the wall for appropriate position for fixing bracket and drill four holes with diameter of 12mm and depth of 80mm with churn drilling as s...

Страница 23: ...ethod three Remote installation of mask Method four Press from front fix four plates with screws 1 K 20341T PNE K 75890T PNE K 24149T K 24151T Method one Press from top Method four Press from front Me...

Страница 24: ...Supporting Board 7 20mm recommended 7 20mm 297 157 2 0 2 0 2 0 2 0 2 0 2 0 Pinch plate installation Screw Air hose Pinch plate Pinch plate Finished wall Faceplate Supporting Board C Method four Cut ap...

Страница 25: ...the air hose to the panel Reserve access panel at front to ensure removal and installation of cover Recommended installation hole size of 146 X 41 mm 146 X 41 mm 41 146 2 0 2 0 Pinch Plate Wall Thick...

Страница 26: ...OF THE OUTLET VALVE Faceplate Faceplate Connect to air hose 3 Dismantle supporting board as shown 3 2 Pay special attention when dismantle supporting board 4 lock nuts all bolts shall align with OPEN...

Страница 27: ...h aside the pivot snaps of the big flush and small flush towards lower left to fix back the bracket Lock the snap Note 7 Lever Snap Snap Locked Fastener Fastener 8 Hold fastener by hand as shown pull...

Страница 28: ...irst then loosen and take out the tighten nut and wash the waste on filtration net with clean water Then reset the tighten nut to the original position A Tighten Close Open Corner Open A Tighten Close...

Страница 29: ...adjust the water level The floating box of the inlet valve is blocked by wastes so the water is leaked from the overflow pipe A No water supply B The water supply stop is closed Readjust the position...

Отзывы: