4.5
Starting the generating set
Once the daily checks have been performed, and having read the instructions and safety regulations carefully:
If the outdoor temperature is above 0°C:
If the outdoor temperature is below 0°C:
1.
Open the fuel tap (A5).
1. Open the fuel tap (A5)
2.
Check that the air filter is in the normal position for use
(D1).
2. Place the air filter in the "low temperature" position (D2).
3.
If the generating set is cold, move the choke control
(A8) to position "
I
".
3. Move the choke control (A8) to position "
I
".
4.
Move the switch (A7) to "
ON
ON
"
" or "
I
I
".
".
4. Move the switch (A7) to "
ON
ON
"
" or "
I
I
".
".
5.
Slowly pull the starter-recoil reel handle (A9) until there
is some resistance, then let it return gently.
5. Slowly pull the starter-recoil reel handle (A9) until there is some
resistance, then let it return gently.
6.
Then pull the starter-recoil reel handle quickly and
sharply until the unit starts.
6. Then pull the starter-recoil reel handle quickly and sharply until the
unit starts.
If the unit does not start, wait one minute before repeating the
process no more than three times.
If the unit does not start, wait one minute before repeating the process no
more than three times.
4.6
Using the electricity supplied
1.
Allow the unit speed to stabilise and the temperature to rise (approx. 3 to 5 min.).
2.
If the choke (A8) was used, return it gradually to its original position.
3.
Connect the equipment to be used to the electrical sockets (A11) on the unit.
4.
Place the voltage selector (A10) in the position corresponding to the voltage you need to use (115V or 230V).
4.7
Switching the generating set off
1.
Disconnect the equipment used, taking care to close the cover for the unit's electrical sockets (A11) .
2.
Allow the unit to run idle for 1 or 2 minutes.
3.
Set the switch (A7) to "
OFF
" or "
O
": the unit will shut down.
4.
Close the fuel taps (A5).
5.
Ensure the unit is properly ventilated and to avoid any risk of fire, wait for it to be fully cool (at least 30 minutes) before
covering it and storing it.
Even when the unit is turned off, the engine continues to give off heat
.
5 Generating set maintenance
As a safety measure, maintenance should be performed on the generating set regularly and carefully by people who have the
necessary experience and are equipped with suitable tools, in respect of current regulations. The maintenance operations to be
carried out are detailed in the maintenance table. The interval for this is supplied as a guide and for generating sets operating with
fuel and oil which conform to the specifications given in this manual. The maintenance intervals can be shortened depending on the
generating set's operating conditions and requirements. It is important to note that the warranty shall not be valid if generating set
maintenance has not be performed correctly.
5.1
Reminder of use
Ensuring maintenance is performed regularly and correctly will guarantee safety and performance.
The oil, filter elements and,
where present, the spark plug, are consumables which must be in good condition for the unit to operate correctly.
Replace them regularly as often as is needed (the reference for ready-to-use maintenance kits is given in the table of
technical specifications where applicable).
The warranty becomes void in the event of failure to respect the maintenance
recommendations. For any questions about a special operation, please contact your nearest agent who will advise and help you.
5.2
Maintenance intervals table
The maintenance frequency is given as an indication only and is for devices using fuel and oil complying with the specifications
given in this manual. The maintenance intervals can be shortened depending on the unit's operating conditions and requirements.
Perform the maintenance operations at the indicated due dates even if the number of hours' operation has not been reached.
The
warranty will be invalidated if maintenance of the unit has not been performed correctly.
After
In hours, months or years, whichever comes first
Operation to be carried out:
5 hours
3 months/
50 hours
Every
3 months/
50 hours
Every
6 months/
100 hours
Every
1 year/
200 hours
Every
2 years/
500 hours
Clean the unit
X
X
Clean the spark arrester
X
Unit
Replace the spark plug
X
Oil
Change
X
X
X
Replace the fuel filter
X
Fuel
Clean the sediment bowl
X
Clean
X
X
X
X
Air filter
Replace
X
Part numbers of parts to be used during maintenance:
RKS1
Major service
to be carried
out by one of
our agents.
France:
0.806.800.107
(call charge)
Major service
to be carried
out by one of
our agents.
France:
0.806.800.107
(call charge)
5.3
Performing the maintenance operations
1.
Shut down the unit and wait at least 30 minutes for it to cool.
2.
Disconnect the cap(s) of the spark plug(s) and disconnect the "-" terminal on the battery (if fitted).
3.
Carry out maintenance in accordance with the information given in this manual and, to avoid the risk of damage to the unit,
only use original parts or their equivalent.
17/22