background image

Fig.#9

9

Fig.#10

10

Carefully align and lower the bowl.
Apply weight to the bowl rim to let the
outlet insert into plastic trap.

Carefully thread the screws into the
brackets, until toilet is secure.
Alternately tighten left and right sides
to prevent pulling the toilet off center.
Install cap to cover screw.

Do not overtighten.

Cap

Screw

Fig.#11

11

Apply caulk around base.

TO CONNECT WATER
SUPPLY

* Flexible hose (not provided) are
recommended to connect the supply
line to the fill valve. If you use a rigid
connection(not provided), take care
not to apply side forces to the bottom
of the fill valve. Be sure the rigid
connection must be fit with supply line
completely to prevent damage shank
by forced connection.

(

)

(

)

Supply Shank*

Supply Shut-Off Valve

Fig.#12

12

IMPORTANT:

Make certain the top is turned to the locked

position. Valve may not turn on if top is not fully in the
locked position.

Before turning on the supply valve for the first

time, follow the steps below to clear sand, debris and rust
from the system:

Make sure water sure water supply is off. Remove valve END
by rotating it 1/8 turn counterclockwise.

While holding a container over the uncapped VALVE to
prevent splashing, turn water supply on and off a few times.
Leave water supply off.

Replace END by engaging lugs and rotating 1/8 turn
clockwise.

Turn on water supply. Check that water level is at the marked
water line.

1/8

1/8

Outlet

Plastic Trap

-5-

Bushing

1328535-T01-B

Содержание SANTA ROSA K-20169T-FNS

Страница 1: ...irted 1PC 400mm K 20170T S Includes Elongated Qc Seat K 22262T 305mm K 20169T FNS K 22261T 305mm K 20169T S K 22262T 400mm K 20170T FNS K 22261T 400mm K 20170T S K 22262T NOTES Observe all local plumbing and building codes Shut off the water supply Seat post holes are on 140mm centers Ensure that the new drain has the correct roughing in dimension This toilet has a 305 400mm roughing in dimension ...

Страница 2: ...EQUIRED Not supplied 254mm 10 adjustable wrench 305mm 12 pipe wrench Metal file file cut Tape measure Tubing cutter Level Hacksaw Putty knife Screwdriver Toilet gasket wax seal Toilet T bolts 2 8mm 5 16 diameter Toilet supply shut off valve 10mm 3 8 recommended If the existing toilet does not have a supply shut off valve below the tank install one before installing the new toilet NOTICE 254mm 305m...

Страница 3: ...NOTICE Do not use white cement or high lime content cements to install this toilet The expansion of cement due to a rise in temperature may make the toilet crack or cause damage Kohler is not responsible for any damage caused by installation with the use of cement Closet Flange mm 67mm 200mm 160 Fig 3 3 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 200mm above the fin...

Страница 4: ...leeve facing away from the toilet NOTE 1 NOTE 2 o 1 21 2 o C Install brackets Plastic Trap Outlet Toilet Gasket Fig 8 8 Install plastic to ground and mounted with 3 set of bolts firmly not supplied 3 NOTE Must use the toilet installation gasket ring not supplied to seal the area where the waste pipe contacts the construction section to avoid leakage Fig 4 4 Fig 5 5 Drain Hole Fig 6 6 3 8 10mm 10mm...

Страница 5: ...nnection must be fit with supply line completely to prevent damage shank by forced connection Supply Shank Supply Shut Off Valve Fig 12 12 IMPORTANT Make certain the top is turned to the locked position Valve may not turn on if top is not fully in the locked position Before turning on the supply valve for the first time follow the steps below to clear sand debris and rust from the system Make sure...

Страница 6: ...flush the toilet Periodically check all connections for leaks for several days following installation Set the tank cover in place on the tank MINOR ADJUSTMENT OF WATER LEVEL Move the snap along OPEN direction OPEN To lower water level Move water cup down to a proper height and rotate screw anticlockwise to achieve the desired water level Refer to float adjustment instructions Screw Snap SCALE 5 1 ...

Страница 7: ... surface E is 2 4mm lower than surface G Screw E Float Water Cup G To elevate water level Rotate screw clockwise and raise float to the desired water level Elevate water cup to a proper position as well Refer to float adjustment instructions Fig 15c 15c Fig 15d 15d Fig 15e 15e SCALE 5 1 OPEN CLOSE 1328535 T01 B ...

Страница 8: ...ertighten If leakage continues replace the gasket E Adjust the tank water level if it is too high 2 No Flush IMPORTANT Use only genuine Kohler parts as shown to avoid property damage 4 Tank takes excessive time to fill 5 There is excessive noise when the tank is filling 3 The fill valve turns on off by itself without the toilet being flushed or it runs allowing water to enter the tank A Reconnect ...

Страница 9: ...fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage Please do not use hard materials like scouring pad to clean product surface especially the product logo CAUTION CAUTION Don t u...

Отзывы: