background image

113362-2-

EA

 (9532)

Copyright 

1995 Kohler Co.

SAN RAPHAEL

 PRESSURE LITE

VITREOUS CHINA

SIPHON JET TOILET

BEFORE YOU BEGIN

HOW TO USE THESE INSTRUCTIONS

Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.

All information in this manual is based on the latest
product information available at the time of
publication. Kohler Co. reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.

These instructions contain important care, cleaning, and
warranty information – please leave for the consumer

INSTALLER HAZARD NOTIFICATION

WARNING: Risk of injury or water damage.
Contents of reservoir under pressure can cause
severe injury. Do not open or service before reading
installation instructions or service instructions. Turn
off water supply and flush unit to release pressure
before attempting any service.

CAUTION: Risk of product damage. Do not use
any oils or lubricants on the Pressure Lite system.

CAUTION: Risk of product damage. The fittings
in this toilet require no adjustment. The fittings in this
toilet are preset. Any adjustment or modifications of
the product are not normal usage and void the
warranty.

WARNING: Risk of injury or product damage.
Handle vitreous china products very carefully.
Vitreous china can break and chip if you overtighten
bolts and nuts.

NOTICE:  

                   

                  

 Follow all

local plumbing and electrical codes.

PRODUCT PROPERTIES

Vitreous china siphon jet toilet.

Pressure Lite

 system.

Water depth from rim is 5-3/4”.

2-1/4” passageway.

For roughing-in and overall dimensions, See
Fig. #3 .

Fixture dimensions are nominal and conform to
tolerances by ANSI/ASME standards
(A112.19.2).

PRODUCT REQUIREMENTS

The supply stop must be 2-5/8” above floor-line and
7-3/4” left of the closet flange centerline.

Since all toilets do not have the same supply
rough-in, you may have to change the location of
the supply stop to install this toilet.

Closet flange must be 12” on-center from wall.

Seat post holes are on 5-1/2” centers.

For most satisfactory operation, the toilet requires
20 p.s.i. static pressure at the supply stop.
Maximum static pressure is not to exceed 80 p.s.i.

ORDERING INFORMATION

Toilet

K-3394

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

When specified:

3/8” supply

K-7637

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Floor bolts

21401

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

NOTE:

For service parts ordering information, see the

separate Service Parts document enclosed with the product.

Содержание SAN RAPHAEL PRESSURE LITE K-3394

Страница 1: ...the Pressure Lite system CAUTION Risk of product damage The fittings in this toilet require no adjustment The fittings in this toilet are preset Any adjustment or modifications of the product are not...

Страница 2: ...toilet If any damage to the vitreous china or Pressure Lite system components is discovered stop the installation and call your dealer for assistance Inspect the complete toilet to ensure that the Co...

Страница 3: ...one of the following three fittings Double fixture fitting Double combination wye and 1 8 bends Double wye and 1 8 bends Fig 2 Double Fixture Fitting Double Combination Wye and 1 8 Bends Double Wye an...

Страница 4: ...wer the toilet over the closet flange and T bolts CAUTION Risk of external leakage Do not lift or rock the toilet after placement a new toilet gasket must be installed if you break the watertight seal...

Страница 5: ...cartridge assembly and is the container for the pressurized 1 6 gallons of water used for each flush The control components consist of the screen adapter backflow preventer pressure regulator and asp...

Страница 6: ...e to reduce the gap NOTE Loss of gap clearance adjustment could cause leakage into the toilet bowl due to the piston not sealing properly This condition could cause a continuous flow of water If the p...

Страница 7: ...ssistance E Screen adapter is clogged E Disassemble screen adapter and clean the screen with a medium to hard bristle brush Refer to installer dealer or Screen Cleaning on Page 6 Replace the screen if...

Страница 8: ...e name of the local Kohler Distributor and the Kohler plumbing fixtures and fittings are warranted free of manufacturing defects Kohler Co will at its election repair replace or make appropriate adjus...

Отзывы: