background image

11

1128227-A01-D   Date: 13/8/2010 

L. Drop-In Installation:

protrusions.
Build stud framing as shown in diagrams, ensuring that 

the top is level. Whirlpool must be installed level at all 

top edges.

Ensure that the stud framing is not interfering with 

pump, air blower and whirlpool plumbing.

Whirlpool must be supported both on the rim and on 

the supporting feet. Do not allow the whirlpool to be 

supported by the rim alone.
Please remember to provide unrestricted access to the 

pump to assist with future maintenance. Access panels 

should be wide enough to allow access to the motor, air 

blower and adjacent plumbing, and should be secured 

by screws to prevent unauthorised tampering.

IMPORTANT:

No motor access, no warranty service.

K. Front & Return Section Installation

Ensure that the bath rim is fully supported.

Build the bath support frame as shown.
When the bath is securely positioned, before the unit 

is fully built in, install tapware, connect plumbing to 

Run water into the bath and check connections for 

leaks.

Pour water around the rail support legs and check for 

any leaks.

with installation.
Please remember to provide unrestricted access to the 

pump to assist with future maintenance. Access panels 

should be wide enough to allow access to the motor, air 

blower and adjacent plumbing, and should be secured 

by screws to prevent unauthorised tampering.

IMPORTANT:

No motor access, no warranty service.

����������

�������� ������������

�����������

�����

��������������

�������������

��������

������� �����������

��������������

��������

�����

�������� ������������

��������������

Min 80 mm

Silicone  sealant

Finished deck (eg. tiles)

Water resistant wall material

Timber framing or brick wall

Finished deck (eg. tiles)

Waterproof  membrane

Water resistant wall material

Timber framing or brick wall

Waterproof membrane

Spa box ledge upstand

Spa box ledge upstand

Silicone  sealant

J. Wall Section Installation Detail

�����������
�������

�����������

��������
������������

����

�����������

���������
�������

�������

�����������
�������

����

�����

���������
�������

�������

�����������

������

�����������
�������

����

��������
������������

����

�����������
�������

���������
�������������

�����������

�����

REBATED INTO WALL

PACKED OUT FROM WALL

�����������

Содержание OVE RECT drop in 1709A-GAB-0

Страница 1: ...10 A 50Hz C Installation Read the entire installation instructions before beginning the installation BEFORE YOU BEGIN BUBBLE MASSAGE BATH INSTALLATION INSTRUCTIONS 1128227 A01 D Date 13 8 2010 Blower...

Страница 2: ...2 REGATTA BUBBLE MASSAGE 11303A GAB 0 1128227 A01 D Date 13 8 2010 OVE BUBBLE MASSAGE 1709A GAB 0 50...

Страница 3: ...3 1128227 A01 D Date 13 8 2010 EVOK BUBBLE MASSAGE 18263A GAB 0 EVOK RECT FREESTANDING BUBBLE MASSAGE 18344A GAB 0 50 837 5 1675 762 408 5 50 36 513 610 81...

Страница 4: ...4 1128227 A01 D Date 13 8 2010 EVOK OVAL BUBBLE MASSAGE 18346A GAB 0 EVOK OVAL FREESTANDING BUBBLE MASSAGE 18348A GAB 0 398 750 50 1700 850 39 50 510 610 398 750 50 1700 850 50 530...

Страница 5: ...5 ESCALE DROP IN BUBBLE MASSAGE BATH 11343A GAB 0 1128227 A01 D Date 13 8 2010 ESCALE FREESTANDING BUBBLE MASSAGE BATH 11344A GAB 0...

Страница 6: ...or property damage Please read all instructions thoroughly before beginning installation including the following Product Requirements WARNING Keep the area around the blower motor clean and free of de...

Страница 7: ...g Install an access panel to allow the pump to be serviced Bath may be installed next to the Bath rim must be fully supported wall or as an island installation Tile Brick or timber B Whirlpool Area Co...

Страница 8: ...TALL THE BATH CAUTION Risk of product damage Do not lift the bath with airjets by the air channels or blower motors or use the air channels or blower motor for structural support of the bath CAUTION R...

Страница 9: ...ion Insert the drain tailpiece into the trap Make sure the bath is level and resting on all support blocks Remove the protective tape from the rim Apply a continuous bead of high quality silicone seal...

Страница 10: ...d with a cord and plug A licensed electrician must install a dedicated GFCI protected 220V 10A grounded outlet Locate the outlet behind the bath and within 610mm of the blower motor Plug the blower mo...

Страница 11: ...im is fully supported Build the bath support frame as shown When the bath is securely positioned before the unit is fully built in install tapware connect plumbing to Run water into the bath and check...

Страница 12: ...Do not use powdered cleaners unless the cleaner is fully dissolved in water Solid substances could block the airjets Do not use bleach or ammonia cleaning solutions Chemically active cleaning solution...

Страница 13: ...move air switch tube and drain C Air switch is faulty or disconnected C Check air tube connections D Blower motor does not work D Replace blower motor 2 Blower motor starts but there are few or no bub...