INSTALLATION
4 5
(LR06×4)
220V
50/60Hz
0.75
0.5
~
1
0.1MPa
2.0L/min
1
1
~
55°C
0.5
~
71°C
0.05
~
0.86MPa
PARAMETERS
Power: DC 4 pieces of AA size alkaline batteries
AC 220V, 50/60Hz
Senser Duration: Less than 0.75s
Shut-off Delay: 0.5~1s
Sensing Distance: Automatic adjustment
Flow Rate: No more than 2.0L/min at 0.1MPa.
Overtime Flowing Control: Automatically stop flushing when
the faucet senses an object for more than 1 minute
continuously
Ambient Temperature: 1~55°C
Supply Water Temperature: 0.5~71°C
Supply Water Pressure: 0.05~0.86MPa
2. Fasten control valve assembly
Unscrew valve cover screws (11) by
screwdriver, open valve cover (10).
Determine control box assembly (9)
installation location per rough-in; then
drill holes, and punch plastic expansion
tube (12) in. Place valve box against
the wall and then mount control valve
assembly on the wall by expansion
screws (13). Keep control box assembly
parallel to the wall.
9
11
10
13
12
2.
控制阀组件的安装固定
拧松
11
10
9
12
13
4
1495657-T2-A
如需在台面开孔,建议直径为20-30mm
1.
龙头与面盆的安装固定
将固定螺杆
(2)
安装到水龙头底部
(1)
处。再把垫片
(
3
)
套在固定螺杆上。并
嵌入水龙头底部的盘槽中。然后将电
源线
(
7
)
和进水软管
(
8
)
穿过安装孔,
从面盆下方将固定橡胶垫片
(
4
)
固定金
属垫片
(
5
)
和固定螺母
(
6
)
对齐固定螺
杆
(2)
向上套入。调整水龙头电源线
(
7
)
及进水软管
(
8
)
的位置。用扳手拧
紧固定螺母
(
6
)
以便把水龙头固定在面
盆上。
When fixing the faucet directly on the
counter top, pls drill the hole of 20-30mm
in diameter.
1. Fixing the faucet and lavatory
Install the mounting stud (2) to the bottom of
the faucet (1), then slip the washer (
3
) over
the mounting stud and put them into the
groove on the spout. Insert the power wire (
7
)
and supply hose (
8
) into the hole from
underside of the lavatory. From underside of
the lavatory, slide the rubber washer (
4
),
meter washer (
5
) and fixed
nut (
6
) onto the mounting stud (2).
Tighten nut (
6
) to make faucet installed
on the lavatory.
1
2
4
3
6
5
7
8