INSTALLATION REQUIREMENTS

Please read the Important Safety Information and specifications sections at 

the front of this guide, and the requirements detailed in this section before 
installing the shower.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:

Plumbing

1. 

The plumbing installation must comply with all national or local water regulations 

and all relevant building regulations, or any particular regulation or practice 

specified by the local water supply company.

2. 

Do not install the product in a position in which service access is limited.

3. 

Decide on a suitable position for the shower (minimum distance of 200 mm from 

the ceiling to allow for cover fit and removal).

4. 

The position of the shower and shower fittings must provide a minimum gap of 

25 mm between the showerhead and the spill over level of any bath, shower 

tray or basin and a minimum gap of 30 mm between the showerhead and the 

spill over level of any toilet, bidet or other appliance with a Fluid Category 5 

backflow risk (see diagram on page 8).

5. 

The shower is suitable for installation within the shower area and is fitted with 

a pressure relief valve. It must be positioned over a water catchment area with 

the controls at a convenient height for the user.

6. 

The shower must be fitted to a waterproof flat and even wall surface.

7. 

DO NOT

 fit the shower to the wall and tile up to the case.

8. 

DO NOT

 seal the gap between the shower and the wall surface.

9. 

The showerhead should be positioned so that it discharges down the centre 

line of the bath or across the opening of a shower cubicle.

10. 

The showerhead must be directed away from the shower unit, during normal 

use the showerhead must not spray directly on to the shower unit.

11. 

DO NOT

  apply  excessive  force  to  plumbing  connections;  always  provide 

mechanical support when making plumbing connections. Any soldered joints 

should be made before connecting the shower.

12. 

This shower is not designed to be plumbed directly from the rear. For rear-entry 

supply, add an elbow to the supply pipe and connect as a rising or a falling supply.

13. 

If pipework and/or electrical cables enter the shower from the rear through a 

hole in the wall provision must be made to prevent water ingress back into the 

wall structure. 

14. 

Only use the inlet connector supplied with the shower. 

DO NOT

 use any other 

type of fitting.

Содержание Mira Sport Thermostatic

Страница 1: ...1 These instructions must be left with the user Installation Guide Mira Sport Thermostatic 9 0 9 8 kW For SPARES ADVICE or REPAIRS Please call us on 0844 571 5000 UK Only...

Страница 2: ...selection and for temperature flow adjustment A unique flow regulator stabilises any temperature changes caused by water pressure fluctuations which can result from taps being turned on or off or toil...

Страница 3: ...at the water in the shower is frozen 6 DO NOT switch the shower on if water starts leaking from the shower case Isolate the electrical supply to the shower immediately 7 DO NOT connect the outlet of t...

Страница 4: ...elf with the part names and to confirm that the parts are included 1 x Mira Sport Thermostatic Electric Shower 3 x Wall Plugs 1 x Compression Nut 3 x Fixing Screws 1 x Olive 1 x Installation Guide 1 x...

Страница 5: ...TOR TERMINAL BLOCK HEATER TANK MICRO SWITCH L MICRO SWITCH R SOLENOID LED LED HOUSING PUSH BUTTON SWITCH BROWN B GREEN D BLUE C RED K BROWN J BROWN G BLACK M BLACK L RED H BLUE E BROWN F B L U E E BLA...

Страница 6: ...Minimum Static Pressure 20 kPa 0 2 bar Maximum Static Pressure 1000 kPa 10 bar Maximum Inlet Temperature 30 C Minimum Inlet Temperature 2 C Inlet Connection 1 2 BSP Male 15 mm Compression Fitting Maxi...

Страница 7: ...on within the shower area and is fitted with a pressure relief valve It must be positioned over a water catchment area with the controls at a convenient height for the user 6 The shower must be fitted...

Страница 8: ...ctions caused by excessive limescale formation are not covered by this shower s guarantee see back page for details 17 The installation must not cause the hose to be sharply kinked during normal use 1...

Страница 9: ...ins system A separate supply must be provided from the consumer unit to the shower 5 DO NOT supply any other electrical equipment including extractor fans or pumps via this product 6 This shower must...

Страница 10: ...move the service tunnel Using the installation template supplied mark the positions of the three fixing holes Note Ensure that there are sufficient lengths of supply pipe and electrical cable to reach...

Страница 11: ...shower from the top or rising entering the shower from the bottom NOTE DO NOT use an incoming supply entering the shower directly from the back Add an elbow to the supply pipe and connect it as a risi...

Страница 12: ...connections and back case are not under any stress due to misaligned pipework or electrical cables Terminal Block Outlet Connector Cold Water Supply Pipe Inlet Connector Strip back sufficient outer c...

Страница 13: ...ervice tunnel Ensure the control dials are aligned with the spindles and replace the cover Tighten the three cover screws 16 17 18 19 20 21 Do not use alternative screws to secure the cover This can c...

Страница 14: ...rise slightly 7 5 10 secs COLD HOT LOW HIGH ECO POWER Turn power control to High Temperature will rise further Adjust temperature as required Flow rate will adjust automatically Push START STOP button...

Страница 15: ...rical supply via the pullcord or wall mounted switch Renew the fuse or reset the MCB RCD If fault persists contact your installer Check case inserts are cut and fitted correctly Check services electri...

Страница 16: ...ead blocked Hose kinked or blocked Other outlets e g Toilet garden hose washing machine etc drawing water while the shower is being used Flush supply pipe Clean inlet filter Contact local water compan...

Страница 17: ...tch faulty Replace as necessary Shower fails to produce hot water when set on Eco High setting ON ECO HIGH Insufficient water supply Possible failure of the microswitch or thermal switch Contact local...

Страница 18: ...se washer for further use Remove the three screws that hold the cover on the shower and remove the cover Remove the service tunnel from the shower Use a suitable spanner to remove the filter from the...

Страница 19: ...roswitch 2 pin 1563 536 Control Belt 1746 458 9 0kW 1746 459 9 8kW Heater Tank 1563 719 Thermal Switch 1746 461 Outlet Connector 1746 446 Switch LED Assembly 416 51 Coil 416 38 Inlet Clamp 1563 540 In...

Страница 20: ...product or consequential loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or replace...

Страница 21: ...Pdf Supplied By http www plumbworld co uk...

Отзывы: