Fluctuating or reduced flow.
Filters blocked.
Water pressure too low.
Flow rate is too low.
Fluctuating water
temperature.
Refer to “
Fault Diagnosis
” in
the “
Digital Mixer Installation
Guide
”.
Maximum blend temperature
too hot or too cold.
Incorrect maximum
temperature setting.
Refer to
“Maximum Shower
Water Temperature”
in the
“
Digital Mixer Installation
Guide
”.
Continuous flow. Shower will
not shut off.
Wireless Controller or Digital
Mixer Valve failure.
Isolate power and water
supplies. Contact our
Customer Services Team.
Shower runs for a short time
(30 - 60 seconds) then flow
reduces, splutters or stops.
Worst when other hot taps
are in use. Less evident when
shower is on full cold.
Air is being sucked down
the vent pipe. (Gravity fed
system).
Warm up setting inadvertantly
selected.
The hot draw off pipe is
positioned too high in relation
to the lowest water level of
the cold water cistern (100
mm min, refer to
“Gravity
Fed Showers”
diagram in the
“
Digital Mixer Installation
Guide
”. Consider increasing
size of cold feed pipe to
cylinder to 28 mm diameter.
Disable Warm-Up feature.
Refer to
‘Function Menu’ -
“Warm-Up”
.
Shower runs for a short time
(3 - 5 minutes)
Cistern capacity insufficient
(230 litres minimum required).
Eco setting selected.
Increase cistern size.
Disable Eco feature. Refer to
‘Function Menu’ - “Eco”
.
Shower runs cool after
a short time (1 - 2 minutes)
then flow
splutters.
Air ingress into hot pipework.
Refer to plumbing
system diagrams under
“Installation”
in the “
Digital
Mixer Installation Guide
”.for
correct connection.
Shower runs cold after
5 - 10 minutes.
Insufficient storage of
hot water in cylinder.
Increase storage of hot water.
Содержание Mira Pixel
Страница 1: ...1 Mira Pixel Wireless Controller These instructions must be left with the user User Guide ...
Страница 12: ...12 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...
Страница 13: ...13 Factory default off Eco Cycle menu to F 2 and press Press or to change setting to on or off ...
Страница 14: ...14 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...
Страница 16: ...16 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...
Страница 18: ...18 Factory default on Clock Display Cycle menu to F 5 and press Press or to change setting to on or off ...
Страница 19: ...19 Press to exit back to Function Menu See section Exit the Function Menu Press to set ...
Страница 22: ...22 Press to set and exit back to Function Menu See section Exit the Function Menu ...
Страница 23: ...23 Factory default 1 Control Frequency Cycle menu to F 7 and press Press or to change channel 1 7 ...
Страница 24: ...24 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...