General Faults
Malfunction
Cause
Remedy
No display.
The batteries are flat or
incorrectly fitted.
Check and rectify.
Shower will not operate.
Water supply isolated.
Flat batteries.
Electrical supply isolated or fuse
blown.
No connection to Digital Mixer.
Control out of range.
Digital Mixer malfunction.
Check water supply.
Replace batteries.
Check electrical supply. If fuse
blown, replace Digital Mixer
Valve PCB.
Reset and recommission. Refer
to Installation Guide
Isolate electrical supply and
reset after 30 seconds
If problem persists, contact our
Customer Services Team.
No flow or low flow from
Shower Fittings.
Showerhead blocked.
Stuck Checkvalve in
Showerhead.
Hose blocked or twisted.
Digital Mixer malfunction.
“
L
” and or “
H
” values set too
low in Flow Range (F6).
Check and clean.
Check and clear or replace
Checkvalve.
Check and clean or release
twist.
Contact our Customer Services
Team.
Change to higher setting.
Drip from showerhead.
A small amount of water may
be retained in showerhead after
showering. This may drain over
a few minutes.
This is normal. Changing
position of showerhead may
vary draining time.
Shower not hot enough.
Maximum showering
temperature set too low.
Digital Mixer fitted incorrectly.
Increase maximum showering
temperature (Function F1).
Make sure hot and cold
water supplies are connected
correctly and delivering a
constant flow and temperature
within the required limits. See
“
Specifications
” in the “
Mira
Pixel Installation Guide
”.
If problem persists, contact our
Customer Services Team.
Incorrect or fluctuating
temperature.
Controller out of range.
Radio interference Warm-up
feature is being used with
combi-boiler.
Refer to “
Fault Diagnosis
” in
the “
Digital Mixer Installation
Guide
”.
+
+
Содержание Mira Pixel
Страница 1: ...1 Mira Pixel Wireless Controller These instructions must be left with the user User Guide ...
Страница 12: ...12 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...
Страница 13: ...13 Factory default off Eco Cycle menu to F 2 and press Press or to change setting to on or off ...
Страница 14: ...14 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...
Страница 16: ...16 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...
Страница 18: ...18 Factory default on Clock Display Cycle menu to F 5 and press Press or to change setting to on or off ...
Страница 19: ...19 Press to exit back to Function Menu See section Exit the Function Menu Press to set ...
Страница 22: ...22 Press to set and exit back to Function Menu See section Exit the Function Menu ...
Страница 23: ...23 Factory default 1 Control Frequency Cycle menu to F 7 and press Press or to change channel 1 7 ...
Страница 24: ...24 Press to set Press to exit back to Function Menu See section Exit the Function Menu ...